TROUBLESHOOTING

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Pump will not run

1. No power or incorrect voltage
2. Brushes worn out
3. Motor has open circuit
4. Motor overheated

1. Supply correct voltage
2. Replace defective part
3. Replace defective part
4. If motor has auto-resetting thermal protector, 

wait 15 minutes for motor to cool

Pump runs but no fluid is 

pumped 

1. Air leak or kink in hose
2. Defective cam or impeller
3. Suction lift too high
4. Inlet clogged
5. Pump too far from liquid

1. Repair or replace
2. Replace defective part
3. Lower pump
4. Clean inlet
5. Relocate pump

Pump will not prime or retain 

prime after operating 

1. Air leak or kink in hose
2. Defective cam or impeller
3. Seal worn
4. Gasket leaking
5. Groove worn in shaft at seal area
6. Suction lift too high

1. Repair or replace
2. Replace defective part
3. Replace defective part
4. Replace defective part
5. Replace defective part
6. Lower pump

Flow rate is low

1. Air leak or kink in hose
2. Defective cam or impeller
3. Incorrect voltage
4. Inlet clogged

1. Repair or replace
2. Replace defective part
3. Supply correct voltage
4. Clean inlet

Shaft seal leaks 

1. Seal worn
2. Groove worn in shaft at seal area
3. Pump head loose on motor

1. Replace defective part
2. Replace defective part
3. Repair

Motor runs too hot

1. Incorrect voltage
2. Excessive discharge pressure
3. Impeller swollen
4. Liquid too viscous
5. Obstruction or kink in hose
6. Insufficient air flow on motor

1. Supply correct voltage
2. Reduce pressure
3. Replace defective part
4. Reduce viscosity of liquid
5. Repair or replace
6. Be sure ample fresh air is available at the motor

PumpAgents.com - Click here for Pricing/Ordering

PumpAgents.com - Click here for Pricing/Ordering

Содержание Little Giant 555702 HRK-360S

Страница 1: ...wed by attaching the black negative lead wire to the ground battery terminal When disconnecting the pump first disconnect the black negative 1 lead wire from the battery ground terminal and then disconnect the red positive lead wire from the positive battery terminal 3 To operate properly the DC direct current version pump must be connected to a steady DC power source or a battery in good conditio...

Страница 2: ...nd the pump head can be fully seated onto the face of the motor g Align the pump head mounting holes with the mounting holes on the face of the motor Reinstall the pump head mounting screws tightening them evenly and snugly Repair Kits 555702 HRK 360S 555706 IRK 360 555713 IRK 360S 555714 ISRK 360S Item Description Component Quantity 1 Screw volute cover 4 2 Volute cover SST 1 3 Cover gasket Nitri...

Страница 3: ... area 6 Suction lift too high 1 Repair or replace 2 Replace defective part 3 Replace defective part 4 Replace defective part 5 Replace defective part 6 Lower pump Flow rate is low 1 Air leak or kink in hose 2 Defective cam or impeller 3 Incorrect voltage 4 Inlet clogged 1 Repair or replace 2 Replace defective part 3 Supply correct voltage 4 Clean inlet Shaft seal leaks 1 Seal worn 2 Groove worn in...

Страница 4: ...ademark of Franklin Electric Co Inc For parts or repair please contact 1 888 572 9933 For technical assistance please contact 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com PumpAgents com Click here for Pricing Ordering PumpAgents com Click here for Pricing Ordering ...

Отзывы: