MAINTENANCE
Draining the Pump
6
5. Gradually open the discharge valve to the halfway point.
• If the pump does not deliver water within seconds, stop the motor and prime pump again.
• Several starting attempts may be necessary to expel all air from the pump and suction lines.
6. Once the pump is fully functioning, completely open the discharge valve and a system outlet.
MAINTENANCE
• Check the pump periodically for loose or rubbing parts.
• Service immediately if any unusual noise, leaks, or vibrations develop.
• Drain the pump should it be subjected to freezing temperatures.
Draining the Pump
All piping and water tanks exposed to freezing conditions must be drained.
For 5-25 GPM pumps:
1. Disconnect the suction line at a connection close to the pump casing and allow the water to drain.
2. Replace the suction line, carefully cleaning the threads and applying fresh thread compound.
For 35 & 45 GPM pumps:
1. Remove the drain plugs and drain the pump casing.
2. Carefully clean the threads and apply thread sealant.
3. Replace the drain plugs.
Disassembly
Motor Removal
1. Shut down system and lock out power.
2. Allow pump components to adequately cool.
3. Drain the pump. Refer to
.
4. Loosen the 2 set screws on the coupling.
5. Remove the 4 bolts, nuts, and lock washers.
6. Pull motor away from pump end.
Square Flange Motor Shaft Adapter Removal
Square flange motors have a motor shaft adapter which must be removed for use on a replacement
motor:
1. Remove motor. Refer to
2. Take off motor canopy.
Risk of severe injury or death by electrical shock.
• To reduce risk of electrical shock, disconnect power before working on or around the system.
Risk of severe injury or death by electrical shock.
• Dangerous voltages are present. Use an appropriate discharge resistor to discharge the capacitor
prior to working on the motor.
Содержание BT4 Series