The profi-air condensate pump reliably discharges condensate from the profi-air 180 flat ventilation unit. It is required if a free 
condensate drain at a gradient of at least 2 % cannot be guaranteed. The delivery includes all necessary parts to connect the 
condensate pump to the ventilation unit.

1.1 Introduction

These installation and operating instructions are intended to help you install fully functional profi-air condensate pumps and  
properly operate them. We recommend that you read these instructions carefully before you install and use the pump. These 
installation and operating instructions can also serve as a reference for service and maintenance work and thus guarantee 
smooth and efficient operation.

1.2 Safety

If used for the intended purpose, the device is safe and reliable to operate. The construction and design are state of the art  
and comply with all relevant DIN / VDE regulations and safety provisions. All safety regulations, warnings and notices of these  
installation and operating instructions have to be complied with; non-compliance might result in personal injury and/or damage 
to the profi-air condensate pump.

1.2.2 Symbols used

1.2.1 Safety regulations

 

Q

Connection and putting into operation of the profi-air  
condensate pump must be performed by authorised and 
qualified personnel only.

 

Q

Installation of the profi-air condensate pump must be  
carried out according to applicable local construction,  
safety and installation regulations.

 

Q

Changes or modifications of the profi-air condensate pump 
are not permitted.

 

Q

Keep these installation and operating instructions near the 
device during the entire life of the profi-air condensate pump.

Installation / operating instructions – profi-air 180 flat condensate pump

4

Содержание profi-air 180

Страница 1: ...profi air 180 flat condensate pump Installation operating instructions Building Technology www fraenkische com...

Страница 2: ...Installation operating instructions profi air 180 flat condensate pump 2...

Страница 3: ...rs cannot be entirely excluded We also reserve the right to make changes to our products specifications and other data Changes may also become necessary as a result of legal material related or other...

Страница 4: ...nce for service and maintenance work and thus guarantee smooth and efficient operation 1 2 Safety If used for the intended purpose the device is safe and reliable to operate The construction and desig...

Страница 5: ...ectly connected to the control of the profi air 180 flat ventilation unit Depending on the operating mode of the ventilation unit A or B it must always be installed on the exhaust air fresh air side T...

Страница 6: ...ousing can operate properly Q Horizontal ventilation unit installation ceiling installation mount condensate pump on the housing wall of the ventilation unit Q Vertical ventilation unit installation w...

Страница 7: ...nit to profi air 180 flat Y cable to connect condensate pump to profi air 180 flat control board 2 pin connector plug for power supply of the condensate pump 2 pin connector plug to connect condensate...

Страница 8: ...i b rat i o n Cal i b raz i o ne 0 120 100 80 60 40 20 110 90 70 50 30 10 0 60 40 100 160 140 200 20 80 120 180 m 3 h Pa Air flo w A B U S B max 45 C ALin ksv ers i o n A Lef t uni t uni t sin i s tr...

Страница 9: ...ali brat i o n Cali braz i o ne 0 120 100 80 60 40 20 110 90 70 50 30 10 0 60 40 100 160 140 200 20 80 120 180 m 3 h Pa Air flow A B US B Digital input J1 J19 RS485 J22 1 2 1 2 1 2 1 2 1 4 2 5 1 3 2 4...

Страница 10: ...1 P2 P4 P1 P2 Pa P3 P4 m 3 Pa m 3 Eins tellw erte Cali brat i o n Cali braz i o ne 0 120 100 80 60 40 20 110 90 70 50 30 10 0 60 40 100 160 140 200 20 80 120 180 m 3 h Pa Air flow A B US B ALinks vers...

Страница 11: ...as been developed and produced for use in so called comfort ventilation systems Any other use is considered improper and can lead to damage to the profi air flat ventilation unit or personal injury wh...

Страница 12: ...o change without notice Cat No 5000 1343 00 01 2018 FR NKISCHE Rohrwerke Gebr Kirchner GmbH Co KG Hellinger Str 1 97486 K nigsberg Germany Phone 49 9525 88 2200 Fax 49 9525 88 92200 marketing fraenkis...

Отзывы: