background image

Pr

e-hea

t/cool

Afterhea

ter

Alarm

Input

CO

Aux

After

cooler

J6

J11

J7

J8

J9

J10

J12

J13

P

ow
er In

24VDC

24VDC

24VDC

12V

USB

Fail

OK

Status

Elec. PH

0V

0V

D+

D-

T

Fire

Therm

+

-

+

-

Input

Damper 1

Open

Open

Damper 2

ModBus

1

+

2

+

T1GTC

+16V

Standby
Switch

Hygro-
stat

Fail
Alarm

Filter
Alarm

+12V

SDA

SCL

TFAH

T2AH

T2AC

0 - 10V

0 - 10V

0 V

0 V

0 V

0 V

0 V

0 V

0 V

0 V

0 V

0 V

0 - 10V

0 - 10V

J1

J2

J3

J4

J5

Humidistat input

Filter alarm output

Fault alarm output

Standby input

0-10 V 

external fan  

activation input

USB connection / firmware

Not active

N

ot

 a

ct

ive

Not active

Fire / smoke 

alarm input

Not active

Not active

Modbus / connection to the 

ventilation unit and / or  

connection to the control unit. 

5.3  Schematic connection diagram

5  Technical data

6  Wiring diagrams

The connection box must be wired and put into operation according to the following wiring diagrams.

All connection activities must be performed in the “dead” state only since otherwise the connection 

box or the mainboard of the ventilation unit may get damaged.

All connection activities must be carried out by authorised and qualified personnel only. In addition, 

applicable local regulations and safety provisions must be complied with.

Installation instructions / operating instructions – profi-air flat / flex connection box

5

Содержание profi-air 180 Flat

Страница 1: ...profi air flat flex connection box Installation instructions operating instructions Building Technology www fraenkische com...

Страница 2: ...tion was prepared with the greatest possible care However we cannot rule out printing errors or translation mistakes Furthermore we reserve the right to change products specifications and other inform...

Страница 3: ...oth and efficient operation 1 2 Safety If used as intended the unit is safe and reliable to operate The construction and design are state of the art and comply with all relevant DIN VDE regulations an...

Страница 4: ...housing which is installed near the ventilation unit 4 Scope of delivery Connection box incl 4 PG threaded connectors Approx 2 5 m of connection cable wired with RJ25 connector plug to connect to the...

Страница 5: ...ive Not active Fire smoke alarm input Not active Not active Modbus connection to the ventilation unit and or connection to the control unit 5 3 Schematic connection diagram 5 Technical data 6 Wiring d...

Страница 6: ...e fire smoke alarm with a relay output When delivered the contact is furnished with a bridge If this contact is interrupted by e g a triggered fire smoke alarm the control system deactivates the venti...

Страница 7: ...ue at the room humidistat is exceeded the control system switches the ventilation unit to mode 3 If the wiring is arranged in parallel several room humidistats can be connected to the contact The digi...

Страница 8: ...il driver The input can be used to connect a standby switch to the ventilation unit Contact closed ventilation unit in operation Contact open ventilation unit out of operation If the system has been s...

Страница 9: ...H T1GTC 16V Standby Switch Hygro stat Fail Alarm Filter Alarm 12V SDA SCL TFAH T2AH T2AC 0 10V 0 10V 0 V 0 V 0 V 0 V 0 V 0 V 0 V 0 V 0 10V 0 10V The input can be used to control the fan mode of the ve...

Страница 10: ...sal Please do not dispose of the connection box with the normal household waste please ask your municipal waste consulting authority about collection points and recycling possibilities Warranty expire...

Страница 11: ...Notes Installation instructions operating instructions profi air flat flex connection box 11...

Страница 12: ...o change without notice Cat no 5000 1342 00 02 2021 FR NKISCHE Rohrwerke Gebr Kirchner GmbH Co KG Hellinger Str 1 97486 K nigsberg Germany Phone 49 9525 88 2200 Fax 49 9525 88 92200 marketing fraenkis...

Отзывы: