11. To adjust the beam range of the sensor (EE models only):

 

a) Shut off water and power supplies.

 

b) Remove the four screws from the top front.

 

c) Remove the eight screws from the bottom of the nose that holds the nose to the shelf.

 

d) Remove the nose to gain access to the sensor adjusting screw located between the two lenses.

 

e) The screw can be tuned a maximum of 3/4 turns. Turn screw counterclockwise to decrease range. The sensor has an adjustable range of   

 

  24" to 48". It is factory set at 27". There is a non-adjustable on-time delay of 0.75 seconds to prevent nuisance actuation of the solenoid    

 

  valve should someone walk by. 

NOTE:

 Walls with a reflective finish i.e., ceramic tile, across from the sensor may cause false actuation no    

 

  matter what the sensor adjustment is for distance. Therefore, do not install the unit in such an area or dull the surface of the wall so it will   

 

  not reflect light.

 

f) The Sensor may be remotely adjust with a PDA. Software may be downloaded from the Franke web site Tech Tips Section.

C. MaintenanCe

The only maintenance operation required is the removal of dirt and lint from the condenser where used. Inspection should be made at 3-month 
intervals. Disconnect the power supply cord, then clean the condenser with a small stiff non-wire or vacuum cleaner attachment brush when 
required. Observance if this procedure will insure adequate air circulation through the condenser so operation is efficient and economical.

D. oVerloaD ProteCtion 

The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in  
case of an overload.

e. luBriCation

This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor, where used, on this unit 
seldom needs oiling, but if required, a few drops of SAE 10 oil should be used.

F. to DisContinue use oF Water Cooler

1.   Close water shut-off valve.

2.  Provide container to catch water to be drained.

3.   On the push button model, disconnect the water supply line at the shut off valve and remove the tank drain plug. Actuate and hold in the  

 

 

pushbutton to open the solenoid valve and completely drain the cooler. Disconnect the power supply cord.

4.   On the EE model, disconnect the water supply line at the shut off valve and remove the tank drain plug. Actuate the solenoid, as explained in   
 

Step B-7 to completely drain the cooler. Disconnect the power supply cord.

5.   Replace plug when draining is complete.

6.   ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER.

*American With Disabilities Act

 

     

      

The warranty and the Underwriters’ Laboratory Listing for this machine are automatically voided if this machine is altered, modified, 

or combined with any other machine or device. Alteration or modification of this machine may cause serious flooding and/or hazardous electrical 
shock or fire. EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE OR AGREEMENT EXPRESSED, 
IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Warning

OPTIONAL - GLASSFILLER

LOCATION

KEPF SERIES

FILTER LOCATION

17 5/8

[448]

PUSH PADS

NON-ELECTRONIC

EYE MODELS ONLY

ELECTRONIC EYE 

MODELS ONLY

5/16 [8] HANGER

MOUNTING HOLES,

2PLCS.

5  3/16

[132]

4 1/32

[102]

8 1/4

[209]

1 1/4 O.D.

TAILPIECE

3/8 O.D.

WATER INLET

WITH STRAINER

AIR

FLOW

1/2 [13]

*33

[838]

ORIFICE

*29 5/16

[744]

*21 1/4

[540]

*18 1/16

[459]

*17

[432]

*16 1/2

[419]

7

[178]

15 7/16 [392]

 4

[102]

 1

[25]

1/4 [6] MOUNTING

HOLES, 4 PLCS.

*19 31/32

[507]

*13 9/32

[337]

6 7/32

[158]

7 1/16

[179]

THIRD ANGLE PROJECTION

ROUGHING-IN

AND 

DIMENSIONAL DRAWING

1/2 [13]

21/4 [57]

7 23/32

[196]

12 3/4

[324]

6 3/8 [162]

5 1/4 [133]

3 15/16

[84]

1 1/2 [38]

14 1/8

[359]

*27

[686]

25/32 

[20]

3/8 WATER SUPPLY 

OPTIMUM LOCATION  

STUB OUT 1[25] INCH

ELECTRICAL

OUTLET OPTIMUM

LOCATION

18 29/32

[480]

T15 DRIVE SIZE

TORX HEAD SCREWS

1 1/4 IPS WASTE

OPTIMUM LOCATION

STUB OUT 1 [25] INCH

KEPV8AC

PUSH BUTTON

18 5/8 [473]

  NOTES:
  1.  TRAP, STOP VALVE AND ELECTRICAL OUTLET NOT FURNISHED.
  2.  ALLOW 4 INCHES [102 MM] MIN. PER SIDE FOR VENTILATION.
* 3.  RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION

    SHOWN. REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS

    USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER. UNIT

    SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30[760]

    BY 48 [1220]. ADJUST VERTICAL DIMENSIONS AS REQ’D TO

    COMPLY WITH FEDERAL, STATE, AND LOCAL CODES.
  4.  ALL DIMENSIONS ARE IN INCHES. DIMENSIONS IN BRACKETS