Electrical connection
Important
- All maintenance and adjustment work on the appliance must be performed
with the power disconnected.
- The connection must be made in accordance with current regulations.
- The connection must be made only by a specialist authorised electrician.
- The appliance operates correctly with alternating current at 220/240 V~
single-phase 50 Hz.
-
THE APPLIANCE MUST BE EARTHED
. If the appliance is connected
directly to the mains, an omnipole switch must be fitted sized for the load of
the appliance with contact opening of at least 3 mm and in compliance with
current regulations.
- The earth cable must not be interrupted by the switch.
ALL MAINTENANCE AND ADJUSTMENT WORK ON THE
APPLIANCE MUST BE PERFORMED WITH THE POWER
DISCONNECTED.
-The appliance is provided with electrical cable without plug; it must be
connected to a plug sized for the load of the appliance, remembering that the
yellow-green cable must be connected to the plug earth connection. The
connection plug must be sized for the load of the appliance.
- After the connection, test the heating elements and operate them for approx.
5 minutes to remove the ambient humidity absorbed.
- The manufacturer accepts no civil or criminal liability if the connection is
not made in compliance with current regulations.