Ensure the following:

– A 3 x 1.5 mm

2

 H05V2V2-F type cable is used when replacing the power cable.

RepaIR

If the power cable is damaged, it must be replaced by the manufacturer or the 

service or by a person with similar qualifications, in order to avoid any risks.

technIcal data

Power supply

220-240 V, 

50-60 Hz

Total power and fuse rating

2900 W, 16 A

Power and heating elements

Radial motor

27 ... 40 W

Light bulb

40 W (x2)

Tangential fan

15 ... 35 W

Heating element, roof

520 W / 124 V

Heating element, floor

1250 W

Heating element, grill

2100 W

DCT heating elements

2650 W