TD-100343.doc
46
4.14. Coffee/hot water and steam temperature sensors
4.14.1. Mode of operation
The temperature sensors measure the temperatures of the thermoblocks so that the
temperatures can be regulated by the software.
4.14.2.
Replacing the temperature sensor for coffee/hot water and steam
Removing the temperature sensor
Unscrew screw from thermoblock base
holder
Disconnect all cable connectors
Detach water connections
Remove complete thermoblock base holder
Remove temperature sensor
Steam
Hot water