A bedroom
ii.
A common room with the installation area
iii.
A room where there is risk of fire.
Before testing the product, make sure that there is no pressure decrease due to malfunction of
another product used in the room where the ventilation holes are present. Ensure ventilation
between the two areas with continuous free openings, e.g. increasing the distance between
the door and the floor. Discharge of combustion products must be performed with a hood so
that they can be discharged either directly or through a chimney/flue.
Electrical connection
Franke hob has a three-pole supply cable with a free terminal. If the hob will remain
continuously connected to the mains, for high voltage category III, install a cut-off device,
which is designed to cut off the current completely, in the opening between the contacts.
Please check the following.
a.)
The plug and the socket must be suitable for 16A;
b.)
They must be easily accessible and located in a manner that no electrical part can be
accessed while plugging/unplugging the product;
c.)
The plug must be taken out without forcing;
d.)
If the product is built-in within a unit of furniture, it must not press on the plug while
the product is plugged in;
e.)
2 electrical appliances must not be connected to the same socket at the same time;
f.)
If the power cable is to be replaced, a new cable of type H05VV-F with dimensions
3x1.5 mm² must be used.
g.)
It is necessary to pay attention to the supporting poles of the null terminals.
(Brown=Phase, Blue=Neutral, Yellow-Green=Grounding)
Note:
Ensure that your mains connection (voltage, maximum power and current values) is in
line with the features of your FRANKE hob.
If the power cable gets damaged, it must be replaced with a specially designed cable or cable
assembly supplied by the manufacturer or authorised service provider.
This product contains grounding only for functional purposes.
BLUE
YELLOW - GREEN
BROWN
Содержание FHNG 302 2G BK C
Страница 2: ...2...
Страница 20: ...20 Figura 3 30 VETRO 30 ACCIAIO INOX 70 ACCIAIO INOX 70 VETRO 60 VETRO 60 ACCIAIO INOX...
Страница 33: ...2...
Страница 51: ...11 Figure 3 30 GLASS 30 INOX 70 INOX 70 GLASS 60 GLASS 60 INOX...
Страница 64: ...2...
Страница 83: ...21 Figure 3 30 VERRE 30 INOX 70 INOX 70 VERRE 60 VERRE 60 INOX...
Страница 96: ...2...
Страница 114: ...20 Figura 2 30 CRISTAL 30 INOXIDABLE 60 CRISTAL 60 INOXIDABLE...