FHMA 604 3G DC / FHMA 755 4G DC/DCL / FHMA 905 4G DCL / FHSM 604 3G DC
FHSM 604 4G / FHSM 755 4G DC / FHSM 905 4G DCL
– 6 –
EN
MODELS‘S CONFIGURATION
MOD.
nr
AUX
nr
SR
nr
R
nr
DC
N
burners
Heat
Source
Total
Rated
Capacity
G20
(m
3
/h)
Total
Rated
Capacity
G30/G31
(g/h)
Air
Neccessary
for
combustion
(m
3
/h)
Tot.
Installed
Gas
Rated
Power
(kW)
Tot.
Installed
LPG
Rated
Power
(kW)
Weight
(net - gross)
(kg)
FHSM 604 4G
1
2
1
4
GAS
0,713
545
15
7,5
7,5
8-9,4 (C)
l
7,1-8,5 (E)
FHSM 604 3G DC
1
2
1
4
GAS
0,742
567
15,6
7,8
7,8
8-9,4 (C)
7,1-8,5 (E)
FHSM 755 4G DC
1
2
1
1
5
GAS
1,028
785
21,6
10,8
10,8
10,5-12(C)
8,9- 10,4 (E)
FHSM 905 4G DCL
1
2
1
1
5
GAS
1,028
785
21,6
10,8
10,8
14- 15,7 (C)
12,5-14,2(E)
FHMA 604 3G DC
1
2
1
4
GAS
0,742
545
15,6
7,8
7,5
8,8-10,2 (C)
FHMA 755 4G DC
1
2
1
1
5
GAS
1,028
764
21,6
10,8
10,5
11,5-13 (C)
FHMA 755 4G DCL
1
2
1
1
5
GAS
1,028
764
21,6
10,8
10,5
11,5-13 (C)
FHMA 905 4G DCL
1
2
1
1
5
GAS
1,028
764
21,6
10,8
10,5
14,5-16,2 (C)
DC = Double Crown SR-Semi-Rapid R = Rapid AUX=Auxiliary C = Cast Iron Grid E = Enameled Grid
Power supply = 220-240 V; Frequency = 50-60 Hz; Power/current = 0,6 Watt
INSTALLATION
Installation and electrical/gas
connection must only be carried out by
specialized and licensed personnel.
The manufacturer declines any liability for
injury to persons or damage to things due to
failure noncompliance with these provisions.
The gas connection must comply with the
regulations in force in the country at the time
of installation.
Z
Ensure that the device is connected
directly to the mains socket. Ensure that
no adapters, no multi-sockets and no
extension cables are used to connect
the device.
Cabinet requirements
This handbook refers to a class 3 built-in gas
hob and type Y for electric part.
The gas pipe must not come into contact with
the sides of any oven under the hob.
For fitted units, the components (plastic
materials and veneered wood) must be
assembled with heat-resistant adhesives (min.
100°C): Unsuitable materials and adhesives
can result in warping and detachment.
The Ventilation of rooms must be in compliance
with local regulation.
The kitchen element must allow sufficient room
for the electrical connections of the appliance.
Important:
These devices are „Y“ type with
respect to the degree of protection against
the dangers of fire. The minimum distance
from the edge appliance is 150 mm for the
side wall, 50 mm for the rear and 700 mm
for any cabinets above it. The appliance is
recommended to be built into 40 mm thick
worktops. In case the dimensions are different,
eventual modifications have to be managed by
the technician.
Note:
if a hood is installed above the hob,
for the distance to be respected refer to the
assembly instructions of the hood.