background image

1 | For your safety

Franke Kaffeemaschinen AG

8

User manual UT40 CM and Pump Modules

CAUTION

Germs in unpasteurized milk

Germs in unpasteurized milk could pose a health hazard.

a)

Do not use any unpasteurized milk.

b)

Only use pasteurized or long-life milk.

Do you have any questions that are not addressed in these instructions?

Please do not hesitate to contact your local customer service partner, Franke

Customer Service, or Franke Kaffeemaschinen AG in Aarburg.

NOTICE

Spoiled milk and ready-to-drink beverages

Insufficient cooling or hygiene can cause milk and ready-to-drink beverages to
spoil.

a)

Only use pre-cooled milk and pre-cooled ready-to-drink beverages

(2.0−5.0 °C).

b)

Only store milk and ready-to-drink beverages in the cooling unit when the

cooling unit is in operation. When the cooling unit is not in operation, e.g.

overnight, store milk and ready-to-drink beverages in a refrigerator.

c)

Clean the machine and cooling unit once a day.

d)

Only touch the suction hose, the inside of the container, and the con-

tainer lid after sanitizing your hands, or wear disposable gloves.

e)

Place the container lid with the suction hose on a clean surface only.

Содержание FCS4072

Страница 1: ...Original operating instructions 20170648 01 8 11 2020 en USER MANUAL UT40 CM AND PUMP MODULES FCS4076 FCS4072...

Страница 2: ...Read the user manual before working on the equipment Keep the manual with the equipment and pass the manual on to the next user if the equipment is sold or transferred to a third party...

Страница 3: ...tion 11 3 1 Position of type plates 11 4 Instructions 12 4 1 Components of the cooling unit with Franke containers and plug in couplings 12 4 2 Cooling unit UT40 FM CM with pump module s 13 4 3 Functi...

Страница 4: ...Only use pre cooled milk and pre cooled ready to drink beverages Remove the milk and ready to drink beverages when the cooling unit is not in use Store milk and ready to drink beverages in a suitable...

Страница 5: ...neral safety concerns WARNING Risk of fatal injury from electrocution Damaged power cords pipes or push on fittings can lead to electrocution a Do not connect any damaged power cords pipes or push on...

Страница 6: ...cabinet in which the appliance is installed are never blocked or obstructed e Maintenance work may be performed by qualified service personnel only f Do not use the appliance if it exhibits any signs...

Страница 7: ...s of the skin or eyes a Observe the hazard warnings on the label of the respective cleaner b Avoid contact with your eyes and skin c Wash your hands after coming into contact with cleaners d Cleaners...

Страница 8: ...milk and ready to drink beverages Insufficient cooling or hygiene can cause milk and ready to drink beverages to spoil a Only use pre cooled milk and pre cooled ready to drink beverages 2 0 5 0 C b O...

Страница 9: ...haz ards c Do not use jets of water or steam for cleaning d Do not expose the device to the elements such as rain frost or direct sunlight e Place the device only on a level stable surface NOTICE Ris...

Страница 10: ...emaschinen AG 10 User manual UT40 CM and Pump Modules 2 SCOPE OF DELIVERY Item description Item number Manual set UT40 CM 560 0604 770 10 l container assembly option Container Lid Hose kit CMB 560 058...

Страница 11: ...G Identification 3 User manual UT40 CM and Pump Modules 11 3 IDENTIFICATION 3 1 Position of type plates 3 1 1 Cooling unit UT 40 CM The type plate is located in the center of the right hand side panel...

Страница 12: ...manual UT40 CM and Pump Modules 4 INSTRUCTIONS 4 1 Components of the cooling unit with Franke containers and plug in couplings Temperature display and temperature control 10 l Franke container Plug in...

Страница 13: ...cooling unit door opens to the right 1 x OM pump module pump module with a hose and a plug in coupling 1 x 10 l Franke container Connections for Franke containers Automatic cleaning system pump modul...

Страница 14: ...o be set Monitoring the fill level when using Franke containers for milk and ready to drink beverages 4 4 Pump module functions Media connection Temperature display Cleaning fitting The pump modules h...

Страница 15: ...find more detailed information on operating configuring cleaning and caring for your cooling unit in user manual supplied with your coffee ma chine In addition the separate cleaning instructions desc...

Страница 16: ...d Pump Modules 4 7 Transport storage decommissioning Clean the device Secure the device against accidents and do not set it up in an inclined position Use suitable packaging for transport and storage...

Страница 17: ...their marking When decommissioned the cooling unit must not be disposed of as municipal waste but has to be separated and taken to a refuse recycling center This is indicated by the symbol on the pro...

Страница 18: ...x 4 x 10 l Optional Franke medium container 4 x 10 l Maximum load capacity of the grate 22 kg Cooling temperature 2 0 5 0 C adjustable Ambient conditions Humidity Max 80 non condensing Ambient tempera...

Страница 19: ...dules 19 Type Country Fuse 10 A Connection 1L N PE Power cord 560 0004 833 CH 560 0004 870 EU Schuko 560 0005 118 GB Type Country UT40 FCS4076 USA CAN Voltage 100 127 V Frequency 60 Hz Power rating 23...

Страница 20: ...lies Disposal 17 D Door Door hinge side 13 E Electronic parts Disposal 17 M Manual set 10 N Noise emission 18 O Options 13 P Plastic parts Disposal 17 Plug in coupling CMB plug in coupling 13 Pump mod...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...Franke Kaffeemaschinen AG Franke Str 9 CH 4663 Aarburg Switzerland Hotline Phone 41 62 787 37 37 Fax 41 62 787 97 37 Internet www franke com...

Отзывы: