6 | Installation
Franke Kaffeemaschinen AG
24
User manual S700
A
A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
Franke Kaffeemaschinen AG
Franke-Strasse 9
CH-4663 Aarburg
Telefon: +41 62 787 3607
E-Mail: [email protected]
Internet : www.franke.com
These drawings and specifications are the property of
Franke Technology and Trademark Ltd. and shall not be
reproduced, copied or transfered to any third party without
the prior written permission of Franke Technology and
Trademark Ltd., Hergiswil, Switzerland
Unit
mm
Scale
NTS
Drawn
Modified
Checked
ECN
500000001421
Article
Number
Description
F SU05
PJ047
28.06.2017
PJ047
28.06.2017
SM055
29.06.2017
Status
Revision
Document ID - Version
Sheet / Sheets
Format
20103676-01
A1
1 /1
-
80
613
340
270
(3)
600
15
5
88
-1
80
12
0
10
0
168
218
28
8
16
8
50
20
0
54
0
70
0
Printed HB028 on 20.07.2017 07:58:04 80 / Released
Only for the coffee
grounds ejection
option
Hose feedthrough in the counter
NOTICE
Overheating damage
If the clearances around and above the machine are too small, heat may accumulate in the machine and lead to
faults.
a)
Maintain the prescribed installation dimensions and clearances.
b)
Take care to ensure that the clearance spaces are not blocked.
Minimum clearances
– To the rear panel: 50 mm
– Above: 200 mm (for filling and removal of the bean hopper)
– To the right: 100 mm (for opening the door)
Optional adjustable feet can be used to compensate for unevenness or differences in height.
6.2.1
Adjustable feet
Feet with a fixed height of 40 mm are included in the scope of delivery if no other option is chosen when ordering
the coffee machine. Adjustable feet with a height of 70 or 100 mm are available as options. Feet with a fixed height
of 7 mm can also be ordered.
Adjustable feet can be used to compensate for unevenness or differences in height.
6.3
Requirements of the water supply
6.3.1
Mains water connection
Water pressure
0,8-8,0 bar
Flow rate
>100 ml/s
Water temperature
<25 °C
Connection to the mains water connection
G3/8" compression fitting and metal hose l = 1500 mm
Only connect with the hose kit provided