12. Remove functional part
12.1
Remove the sealing cap.
12.2
Remove the safety ring.
12.3
Remove the pressure cap and spring.
12.4
Use a socket spanner to unscrew the functional part.
12.5
Reassemble in the reverse order.
13. Fault correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
Fault
Cause
Remedy
Water does not flow
at all
– Water supply interrupted
➯
Restore
– Flow volume regulator closed
➯
Open it
– Functional part faulty
➯
Replace it
Water flows
continuously
– Functional part faulty
➯
Replace it
– Volume flow rate controller is closed
➯
Open it
Water flow too weak
– Flow volume regulator not fully
opened
➯
Open it
– Supply pressure too low
➯
Check it
– Volume flow rate controller not fully
opened
➯
Adjust it
– Flush volume adjustment incorrect
➯
Adjust it
Water flow too large
– Flush volume adjustment incorrect
➯
Adjust it
– Volume flow rate controller not fully
opened
➯
Close it