ZMI
_001_
2030
0204
53-A
Q
CT0073
_#SE
N
_#AQ
U
_#V
2.f
m
- 12 -
17. Setting Flow Time
You can adjust the flow time from 10 s to 5 min using the remote control (not part of
the scope of delivery; see Accessories,
18. Setting Range
You can adjust the range for body reflection using the remote control (not part of the
scope of delivery; see Accessories,
).
19. Hygiene Flush
☞
At the factory, the hygiene flush function is set so that water flows for 10 seconds
24 hours after the flush was last activated.
You can adjust the hygiene flush parameters using the remote control (not part of
the scope of delivery; see Accessories,
You can choose an interval of 0, 8, 24, 48, or 72 hours for the hygiene flush function
(0 = hygiene flush deactivated). You can adjust the flow time from 10 seconds to
10 minutes.
The hygiene flush cycle can be calculated from the interval plus the flushing time
with a tolerance of ± 5%.
Display of hygiene flush on fitting
19.1
Hold your hand around 10 cm from the sensor for 3 seconds.
19.2
Between the 1st and 2nd flashing of the LED, remove your hand from the sensor.
• Hygiene flush active: The LED flashes quickly 4 times.
• Hygiene flush inactive: The LED flashes slowly twice.
Activation/deactivation of hygiene flush on the fitting
19.3
Hold your hand around 10 cm from the sensor for 3 seconds.
19.4
Between the 6th and 8th flashing of the LED, remove your hand from the range of
the sensor.
• The LED does not flash.
19.5
After between 3 and 10 seconds, hold your hand around 10 cm from the sensor
again.
19.6
Once the LED has flashed three times, remove your hand from the range of the
sensor.
• The LED flashes quickly 4 times. The hygiene flush is active.