- 5 -
ZMI
_001_
2030
0394
77-A
C
EX90
01_#
SEN_#
AQU_#
V
1.
fm
5. 5. Application
Power supply in compliance with EMC product standard and Safety. Stabilized DC
power supply. Plastic housing for DIN rail mounting. Short-circuit-proof design, with
spring terminals. With safety shut-down for connected bistable solenoid valves.
Maximum cable length 10 m with cable cross section 0.32 mm²
6. Technical Specifications
7. Dimensions
Standards / Approvals
Safety
EN 60335-1
EN 60950-1
EN 61558-2-16
EMC
EN 55022
EN 55024
EN 61000-3-2
EN 61000-3-3
EN 61000-6-2
EN 61000-6-3
EN 61204-3
RoHS
Input:
100-240 V ac / 50-60 Hz
Voltage range:
85-264 V ac
Frequency:
44 to 66 Hz
Input current:
typ 1.05 A at 230 V AC
Output:
Output voltage:
6,75-7.5 V / 12-14 V
Output current:
4 A
Ripple:
< 150 mVpp (at 20 MHz bandwidth)
Type of protection:
IP 20
Ambient temperature:
-25°C to +55°C
Storage temperature:
-40°C to +85°C
LED signalling:
Green LED
Special features:
Short-circuit proof and open-circuit proof