- 5 -
ZMI
_001_
2030
0539
54-F5L
M
1019
_#SE
N
_#AQ
U
_#V1
.f
m
5. Application
F5LM single-lever mixer with mixing cartridge with ceramic disks and thermostatic
scald protection according to DIN EN 1111, preset to a maximum of 41°C for the
fitting unit. For connection to hot and cold water supply.
With one connection above the other. Fitting housing made of low-lead brass, in
accordance with the requirements of the TrinkwV and DIN 50930-6
recommendations.
6. Technical specifications
7. Scope of delivery
8. Dimensions
9. Installation example
10. Assembly
☞
Important!
Note the installation position of the filters.
10.1
Insert the filters (a).
☞
Important!
Take care that the hole of the tension bolt (b) is vertically aligned.
10.2
Insert the fitting (c) and secure with the grub screw (d).
Recommended flow
pressure:
1-5 bar
Maximum operating
pressure:
10 bar
Volumetric flow:
0.06 l/s at a flow pressure of >1.0 bar
Calculation of flow rate:
0.06 l/s
0.06 l/s
Quantity
Name
1
F5LM single-lever mixer
1