10. Preparing electrical connection by the customer
Warning!
• The power supply (not included in the scope of delivery) must be set up outside of
the wet area, in a separate room.
• Only operate the coin-activated switch with protective extra low voltage (SELV)
24 V DC.
• Secure the electric connection with an earth leakage circuit breaker (RCD) for a
maximum nominal fault current of 30 mA.
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
☞
The system line (not included in scope of delivery) for connecting the power supply
to the fittings and the coin-activated switch must be installed in a conduit (to be
supplied by customer) and looped through.
11. Assembly Instructions
Installing the electronic T-junction
☞
Important!
The components of the electronic T-junction must be installed only when they are in
a dead condition.
☞
Recommended system lines see
Chapter 17
, Accessories.
When using other cables for the system line, note the different colour coding. The
outer diameter must not exceed 7.5 mm.
11.1
Strip the shielding (a) off from the system lines (approx. 40 mm).
11.2
Fit the union nut (c) on to the system line (b) up to the stop.
☞
The cable cores are marked with numbers 1 through 4.
11.3
Latch the cable cores (d) into the cable core guides (e) according to their colours.
11.4
Cut off the protruding ends of the cable core so that they are flush, i. e. so that they
do not protrude.
11.5
Place the union nut (c) on the electronic T-junction (f) and tighten with the required
torque (1.2 Nm).
A
B
1
brown
red
2
white
white
3
blue
blue
4
black
black
A: Union nut
B: FAR-Order-No. 84-032-12.468
FAR-Order-No. 84-032-12.534
FAR-Order-No. 84-032-12.563
FAR-Order-No. 84-032-12.720