9
18
-05.
306
e_GB
.f
m
15. Adjusting the Flush-Volume
15.1
Remove the cover plate.
15.2
Set the flow volume regulator to "fully opened" (see
15.3
Disconnect the mains voltage supply for min. 60 seconds. The flush-volume setting
is activated.
15.4
Reconnect the voltage supply.
15.5
Wait for the confirmation flashing (1x long 3x short).
15.6
Hook in the cover plate.
15.7
Hold your hand a distance of 5-10 cm in front of the sensor. The LED flashes quickly.
15.8
After 5 seconds the indicator lamp automatically turns off.
15.9
Move your hand out of the sensor-detection area (at least 60 cm away).
15.10
Hold your hand a distance of 5 - 10 cm in front of the sensor. The LED flashes.
2 flashes, pause, 3 flashes, pause, 4 flashes, etc.
15.11
Move your hand out of the sensor-detection area (min. 60 cm) after the required
flash sequence is seen. After this, the fitting flushes with the set flush-volume. After
flushing, the flash sequence of the corresponding flush-volume is displayed.
P: Pause
15.12
Low flush-volume
15.13
High flush-volume.
Flush-volume OK:
15.14
Wait 20 seconds outside of the sensor-detection area (the fitting switches
automatically to the normal operating mode).
15.15
Flush-volume NOK:
15.16
Hold your hand a distance of 5 - 10 cm in front of the sensor. The LED flashes.
2 flashes, pause, 3 flashes, pause, 4 flashes, etc.
16. Adjusting the Flush Flow-rate
16.1
Remove the cover plate (see
16.2
Adjust the flush flow-rate.
+ Increase flush flow-rate
– Decrease flush flow-rate
16.3
Содержание 5526 11 24-F
Страница 57: ...57 18 05 306e_PL fm Notizen...
Страница 58: ...58 18 05 306e_PL fm Notizen...
Страница 59: ...59 18 05 306e_PL fm Notizen...