14. Fault correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
15. Replacement parts
Fault
Cause
Remedy
Water does not flow
at all
– Stop valve or flow volume regulator
closed.
➯
Open it
– Upper section faulty
➯
Replace it
– Activation valve faulty
➯
Replace it
Water flows
continuously
– Upper section faulty
➯
Replace it
– Activation valve faulty
➯
Replace it
Duration too short or
too long
– Flush volume adjustment incorrect
➯
Adjust it
– Upper section faulty
➯
Replace it
Water flow too weak
– Stop valve or flow volume regulator
not fully opened.
➯
Open it
– Supply pressure too low
➯
Check it
– Flush volume adjustment incorrect
➯
Adjust it
Water flow too large
– Flush volume adjustment incorrect
➯
Adjust it
Designation
Order No.
1 Activation valve . . . . . . . . . . . . . . . . . 82-100-10.964
2 Cover plate . . . . . . . . . . . . . . . . . . . . . 82-100-10.970
3 Frame with profile seal . . . . . . . . . . . 82-100-10.890
4 WC flush valve . . . . . . . . . . . . . . . . . . 82-100-10.760
4a Upper section . . . . . . . . . . . . . . . . . . 2600 24 30
5 Complete outlet connection . . . . . . . 82-100-10.644
6 Remote activation hose
Specify length in meters
. . . . . . . 82-039-10.036
Replacement parts set for DN 20 consisting of:
Rubber parts
Spring
Seals . . . . . . . . . . . . . . . . . . . . . . 82-500-01.003