![Franke 2000101161 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/franke/2000101161/2000101161_installation-and-operating-instructions-manual_2327357005.webp)
5
18
-05.
745
b-GB
.f
m
5.
Application
PROTRONIC-C A3000 open non-touch, opto-electronically controlled washbasin
mixer DN 15. Design with temperature-selector lever. With facility for externally
controlling options such as fittings settings and communication via ECC function
controller. Adjustable flow duration, down to the second.
2000101161 ... for connection to hot and cold water supplies
2000101162 … for connection to pre-mixed warm water or cold water supplies
Control functions:
– Hygiene flushing (10 seconds), 24 hours after last usage
– Safety switch-off when there is continuous reflection
Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning switch-off
6.
Technical Specifications
Minimum flow pressure:
1.0 bar
Recommended flow
pressure:
1–5 bar
Maximum operating
pressure:
10 bar
Calculation flow rate:
2000101161
0,07 l/s
0,07 l/s
2000101162
0.10 l/s
Volumetric flow:
0.10 l/s for 3 bar flow pressure
Operating voltage:
24 V DC
Power consumption:
2.5 W
Communication:
Ethernet via ECC function controller
Type of protection:
IP 68
Содержание 2000101161
Страница 43: ...43 18 05 745b RU fm 4 5 PROTRONIC C A3000 open DN 15 ECC 2000101161 2000101162 10 24 ECC Ethernet DVGW W 551...
Страница 47: ...47 18 05 745b RU fm 12 DIN 1988 12 1 a b c 12 2 d 12 3 T 13 13 1 13 2 24...
Страница 48: ...48 18 05 745b RU fm 13 3 a 14 15 16 17 18 19 16 1 AQUA 3000 open ECC T 16 2 17 17 1 a b 22...
Страница 50: ...50 18 05 745b RU fm 20 20 1 20 2 20 3 a 20 4 b c 20 5 d 20 6 e 20 7 f 20 8 21...