FAR-Best.-Nr.: 2000101102
16.5
Close the water supply.
16.6
Take the eye shower (c) out of the wall bracket.
16.7
Loosen the eye shower (c) from the hose (f).
16.8
Replace the filter (e).
☞
Important!
Note the installation position of the filter.
☞
The handle bar (d) must face forwards.
16.9
Reassemble in reverse order.
17. Replacing the flow rate regulator
17.1
Close the water supply.
17.2
Take the eye shower (a) out of the wall bracket.
17.3
Loosen the hose (b).
17.4
Use a bent wire to lift out the flow volume regulator and replace it.
Caution!
Note the installation position of the non-return valves.
☞
Do not forget the seal.
17.5
Reassemble in reverse order.
18. Replace the non-return valve
Caution!
The non-return valve must be replaced every 2 years.
18.1
Loosen the screw (a).
18.2
Remove the shower base (b).
18.3
Remove the spray heads (c) and the seals (d).
18.4
Unscrew the attachment part (e).
18.5
Remove the disc (f).
18.6
Push out the non-return valve (g).
18.7
Reassemble in reverse order.