6
ZMI
_001_
2000
1010
87-ZAQ
U
A09
1_#S
EN_#A
QU_#V
5.f
m
Adjusting the extension of the flow duration/flushing time
8.5
Use the + and – (
) keys to adjust the extension of the flow duration in individual
steps.
• The LED in the sensor of the fitting flashes:
– 4 × short for each adjustment by one step
– 2 x long when the respective end setting is reached
Switching off the fitting
8.6
Press the
OFF key.
• The fitting is now permanently closed.
• The LED in the sensor of the fitting flashes:
– 3 × short, break, 3 × short, break, ...
8.7
Press the
OFF key again.
• The fitting is ready for operation.
9.
Wash Fitting Settings
Setting for continuous flow
For continuous flow, a time of 3.5 min or 11 min can be set (default 3.5 min).
9.1
Press the TEST key.
9.2
Press the
OFF key repeatedly until the required mode has been set.
• The time for the continual flow is set.
• The LED in the sensor of the fitting flashes:
– 2 × long = 11 min continual flow time
– 4 × short = 3.5 min continual flow time
9.3
Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
☞
This function is not available for products manufactured before 1 June 2003. Press
the corresponding buttons to switch the fitting off.