11. Remove functional part
11.1
11.2
Close the flow volume regulator.
11.3
Remove the safety ring.
11.4
Remove the pressure cap and spring.
11.5
Use a socket spanner to unscrew the functional part.
11.6
Reassemble in the reverse order.
12. Fault correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
Fault
Cause
Remedy
Water does not flow at
all
– Water supply interrupted
➯
Restore
– Flow volume regulator closed
➯
Open it
– Functional part faulty
➯
Replace it
Water flows conti-
nuously
– Functional part/upper section faulty
➯
Replace it
Water flow too weak
– Flow volume regulator not fully
opened
➯
Open it
– Supply pressure too low
➯
Check it
– Flush volume adjustment incorrect
➯
Adjust it
Water flow too large
– Flush volume adjustment incorrect
➯
Adjust it