![Frank FEM 718 MSE-Z Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/frank/fem-718-mse-z/fem-718-mse-z_operating-instructions-manual_2326762017.webp)
- 16 -
11.
Troubles, causes and troubleshooting
Trouble
Possible cause
What to do about it
Machine is not
No current; low voltage
Have an expert:
running or switches
Interruptance in power supply
check the fuse of local
off during operation
installation and control fuses
in the circuit box of the machine,
replace if necessary; check supply
cable, wall socket and voltage
Fuse(s) in main switch cabinet
Have an expert check the cause
blown out
and have the fuses replaced.
Low or excessive voltage,
Provide required voltage
overcurrent release switches off
Excessive pump pressure,
See under "Trouble" "Excessive
overcurrent release switches off.
pump pressure"
Threephase current motor runs
See under "Cause" Disturbances
on 2 phases, overcurrent release
in the electric power supply"
switches off
Pump fails to
Leakage in pump or in
Check and retighten screw
reach required
chemical suction hose
connections, replace sealings
pressure
if necessary, tighten hose clips;
check dosing valve for leaks,
replace, if necessary
Leakage in pressure system
Have an expert check pipes,
hoses, fittings for leakage,
have leaking parts sealed or
replaced, if necessary