background image

2 Installation instructions

2.1 Warning to the user

All the local and national
regulations, and in particular
those relating to national and
European standards, must be
observed when installing the
appliance.
A n

i n c o r r e c t l y

i n s t a l l e d

heating appliance can cause
serious accidents

(chimney

f i r e s ,

b u r n i n g

o f

p l a s t i c

insulation materials, in partition
walls, etc.).
T h e i n s u l a t i o n o f b o t h t h e
appliance and the exhaust gas
pipe has to be reinforced and
done according to the Standards
and the Building Regulations for
safety reasons. The installation
must be carried out according to
the Standards and the Building Regulations.

Failure to respect the mounting instructions leads to
engage the responsibility of the one doing the
installation.

The manufacturer’s responsibility shall be limited
to the supply of the appliance.

2.2 Location of the unit

Ventilation :

For satisfactory appliance operation with a natural
draught, check that sufficient air for combustion is
available in the room.
in houses equipped with one VMC (controlled
mechanical ventilation), this one aspire and renew the
ambient air ; In this case, the residence is under slight
low pressure and a non-sealable external air intake
must be installed in addition to the chimney itself, at
least 50cm² in section.

Position of the unit :

For new installations, select a central position within the
house, to provide a good heat distribution around the
building.
The heat distribution towards the other rooms will be
made through the communicating doors.
These rooms must be in negative pressure or must
include ventilation gratings.

Floor and walls :

Make sure that the floor can support the weight of the
appliance, its surroundings and the hood. In the
contrary the floor needs to be reinforced with a concrete
screed to distribute this load.
Make sure they are not combustible or covered with
combustible material (as per the Building regulations).
O t h e r w i s e

i t

m u s t

n e c e s s a r y

t o

i n s t a l l

a

non-combustible protection.
There must be a clearance of at least 150 mm at each
side of the appliance and at the back of the appliance
from a non-combustible wall.

This measurement may be reduced to a minimum gap
of 50 mm when the non-combustible wall is at least
200 mm thick.
This distance must be extended to a minimum
clearance of 425 mm from any combustible materials.
When using a single wall flue pipe, there must be a
clearance (A) of at least three times its diameter (B)
from any combustible materials.
If the appliance has to be located in an opening, this
distance must be extended to a minimum clearance (A)
of 375 mm from the pipe or the stove body to any
combustible materials.

Hearth :

The appliance must stand on a fireproof hearth.
It is possible to provide a hearth made of non
combusible board/sheet material or tiles at least 12 mm
thick (C).
Constructional hearths should be constructed of solid
non combustible material at least 125 mm thick
(including the thickness of any non combustible floor
under the hearth).
The hearth must protrude at least 225 mm in front of the
stove and 150 mm each side.
If the hearth is constructed on timber, there must be a
clearance of at least 250 mm from the timber to the top
surface of the hearth. See section J of the Building
regulations.

2.3 Flue

Existing flue :

The chimney must comply with Current

Building Regulations. If in doubt, consult your Dealer or
local Building Inspector.

-

The flue must be in good condition and must provide
sufficient draught.

-

The flue must be suitable for the installation of solid
fuel burning appliances and comply with Current
Building Regulations.

-

The flue must be clean. It should be swept to remove
soot and dislodge tar deposits.

-

The flue must be well insulated. If the flue inner wall
surfaces are cold, a good thermal draw is impossible

4

Technical manual “1274”

“SAVOY MK2” - model : 134 08 09

Installation instruction

1 5 0   m m

4 0 0   m m

7 0 0   m m

9 0 0   m m

1 5 0
m m

7 0 0   m m

9 0 0   m m

1 5 0

1 5 0

1 5 0

3 0 0

1 5 0

B

A

A

C

1 5 0

Figure 2 - Clearances

Содержание SAVOY MK2 134 08 09

Страница 1: ...Output wood 8 kW Output coal 7 kW Technical manual to be saved by the user for future reference STAUB FONDERIE SARL with the capital of 6 359 540 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM...

Страница 2: ...e shooting p 9 Spare parts p 10 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality of its appliances and is committed to meet its customers needs FRANCO BELGE which can...

Страница 3: ...12 Nominal heat output kW 7 2 Efficiency 71 9 Co 13 O2 0 13 1 3 Appliance description Wood stove in conformity with DIN EN 13240 2005 10 Intermittent burning heating appliance Detachable flue spigot f...

Страница 4: ...tible material as per the Building regulations Otherwise it must necessary to install a non combustible protection There must be a clearance of at least 150 mm at each side of the appliance and at the...

Страница 5: ...diameter of 139 mm The stove is set from the factory with a top outlet 2 5 Top flue outlet Figure 3 First remove the flue baffle A The stove is set from the factory with a top outlet Do not remove the...

Страница 6: ...ss for cleaning The spigot should be connected to a minimum of 125 mm flue system and in that case the appliance is capable of burning untreated wood and recommended solid fuels 2 8 Pre utilisation ch...

Страница 7: ...not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash ma...

Страница 8: ...pliance is cold Remove the ash drawer using the tool provided Empty the ashes carefully with regard to the live embers 3 5 Maintenance of the Chimney Very important In order to avoid any incident chim...

Страница 9: ...mall wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up The flue damper is closed Open the flue damper Flue duct is cold Burn paper and kindling wood to increase heat Ro...

Страница 10: ...ic glass 402 x 322 01 17 189103 Screw 27x8x6 02 18 189104 Screw 6x22 02 19 189825 Screw M5x6 01 20 205362 Back panel 01 21 222581 Flue baffle 01 22 236138 Reducing plate 01 23 237406 Reducing plate 01...

Страница 11: ...3 2 1 4 1 4 3 8 4 5 2 1 2 0 3 4 6 7 3 3 4 0 8 4 6 4 1 4 1 3 4 2 1 3 3 9 2 7 4 4 2 3 1 2 3 6 1 7 2 4 2 2 5 3 7 1 4 3 2 5 1 0 1 6 9 1 5 1 8 1 0 2 5 1 0 2 5 2 5 1 0 1 9 3 1 4 2 1 4 3 5 3 0 1 7 1 8 2 9 2...

Страница 12: ...he exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or...

Отзывы: