2.8. Recommendations for installation
and insulation

For all the various installation configurations, the hearth
plate must be made from incombustible material. If the
walls of the chimney are made from combustible
material, the installation should be carried out as
follows (figure 9, page 8).
In the case of use of incombustible materials, we
recommend that an air space be left around the
appliance.

2.9. Setting

Figure 11
-

Slide the insert fire in the chimney hearth by lining up
the cast iron fascia with the front of the chimney casing

-

Replace the cast iron flue collar by fitting it in the flue
pipe and temporarily refit the flue damper control

-

Refit the flue damper control and the flue damper. The
handle of the flue damper control must point upwards
when the damper is closed (fig. 10)

If the chimney has a

wooden beam

, it must be

protected by fitting underneath it a metal strip (fig. 11),
with isolating fibre of air pocket between the beam and
the strip.

2.10. Electrical connection

The electric installation must be carried out in
accordance with the regulation in force.

634 07 46 only

Electrical connections should not be made until all other
installation operations are completed (fixing, assembly,
etc.).
Complies with :

- Low tension Directive 73/23/CEE, under standard
NF-EN60335-1.
- Electromagnetic compatibility Diretive 89/336/CEE
The fans electrical requirement is 230 V ~ 50Hz. Plug in
the power cable on a wall socket with a link to an earth
socket and protected by a 1 A fuse-wire.
Please note : When using a variator of speed (optional),
connect the fans on the variator

(Use only the

FRANCO BELGE variator ref. V634 10 37).
Very important !

The power supply cable is resistant to

temperatures of 300°C. Ensure that the same type of
cable is used if it is replaced.

2.11. Hot air outlets

In the case of the insert fire being the hearth of a
chimney to be built, it is possible to fit two outlets to
diffuse air to adjacent rooms. In this respect :

-

Remove the blanking plates on the casing on top of the
appliance (fig. 13),

-

Secure the 5 mm O.D. screws

-

Fit the flue collars supplied by rotating them,

-

Use

insulated

flexible pipe dia. 125 mm.

-

Avoid using pipes longer than 6 meters.

-

Eventually use hot-air vent controls.

Technical manual “1248”

9

“HEKLA” - ref. 634 07 46 & 634 07 47

Installation instructions

Figure 10 - Flue damper control

Figure 11 - Setting

Figure 12 - Electrical wiring

T

: Safety thermostat

V

: Fans

V-

V

: Automatic speed

control (optionnal)

Ph

: Phase

N

: Neutral

BU

: blue

BN

: brown

BK

: black

GN

YE

: green/yellow

Beam

protection

Содержание HEKLA 634 07 46

Страница 1: ...i ge Social 2 rue Saint Gilles 68230 TURCKHEIM RCS de Colmar SIREN 444 881 953 Si ge Administratif et usine BP 73 59660 MERVILLE T l phone 03 28 43 43 00 Fax 03 28 43 43 99 Mat riel sujet modification...

Страница 2: ...s avant mise en service p 11 Acc s aux ventilateurs p 11 Entretien de la chemin e et ramonage p 11 Instructions pour l utilisateur p 12 Combustible p 12 Allumage p 12 Ventilation de l insert p 13 Cond...

Страница 3: ...Volume de chauffe corrig m3 240 240 D pression du foyer l allure maxi Pa 12 12 D pression du foyer l allure mini Pa 6 6 D bit massique des fum es g s 8 20 8 20 Temp rature des fum es C 340 340 Rendem...

Страница 4: ...rayonnement des parois du foyer et de l avaloir L air chaud s levant naturellement est restitu soit dans la pi ce au travers de la grille de diffusion de la hotte ou au travers du diffuseur en fa ade...

Страница 5: ...hotte dans le cas contraire le renforcer par une chape en b ton pour r partir cette charge Dans tous les cas il est pr f rable de sur lever le foyer pour loigner le plancher du rayonnement tr s import...

Страница 6: ...ns 6 Notice de r f rence 1248 HEKLA r f 634 07 46 634 07 47 Instructions pour l installateur 2 0 4 5 2 0 s i H 5 m H Figure 4 D voiement du conduit de fum e D D D D 2 3 4 5 6 7 8 9 1 1 0 9 9 3 0 c m 4...

Страница 7: ...mm b bloquer la buse de longueur X 530 sur la collerette en cas de d voiement du conduit utiliser un tuyau flexible c si le sol de l tre est rugueux poser une plaque m tallique pour faciliter la mise...

Страница 8: ...46 634 07 47 Instructions pour l installateur Figure 9 R glementations d installation D Distance de s curit 16 cm mini partir de la paroi int rieure du conduit ne pas isoler la partie non combustible...

Страница 9: ...t le bandeau 2 10 Raccordements lectriques L installation lectrique doit tre r alis e conform ment la r glementation en vigueur Si vous poss dez le mod le 634 07 46 les raccordements lectriques ne ser...

Страница 10: ...ure 6 m Pr voir des bouches de diffusion r glables 2 12 Chicane de fum e Figure 14 La chicane bloqu e sur la grille de foyer au d part de l usine doit tre mise en place l int rieur de la chambre de co...

Страница 11: ...uter du mastic r fractaire aux coins de la nervure de la fa ade avant de remonter celle ci 2 15 Entretien de la chemin e et ramonage Tr s important Afin d viter tout incident feu de chemin e etc les o...

Страница 12: ...de bois trait traverse de chemin de fer poteau t l graphique chute de contreplaqu ou d agglom r palette etc provoque rapidement l encrassement de l installation suies bistre goudron nuit l environnem...

Страница 13: ...rdement et le conduit de fum es Ouvrir la porte vitr e et nettoyer toutes les parois de la chambre de combustion nettoyer la grille de foyer Le nettoyage de la vitre sera r alis e lorsque l appareil e...

Страница 14: ...te etc Emanation de fum es l allumage Le clapet de tirage est ferm Ouvrir le clapet en grand Le conduit de fum e est froid R chauffer le conduit en faisant br ler une torche de papier dans le foyer La...

Страница 15: ...Notice de r f rence 1248 15 HEKLA r f 634 07 46 634 07 47 Notes Notes...

Страница 16: ...mique 9 5 A B 1 08 m 15 181622 Tresse de c ramique 8 A B 2 56 m 16 188513 Ventilateur A 02 17 188814 Verre c ramique 504x315x4 A B 01 18 181632 Joint 6 A B 1 m 19 200174 Dessous A B 01 20 217128 Envel...

Страница 17: ...Pi ces d tach es 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 2...

Страница 18: ...les fusibles les r sistances lectriques les ventilateurs 2 les pi ces d usure ou en contact avec des temp ratures importantes savoir soles et grilles foy res plaques de fond d flecteurs cendriers pein...

Страница 19: ...000 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM RCS Colmar SIREN 444 881 953 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 00 Fax 00 333 28...

Страница 20: ...ffle mounting p 11 Access to the fans p 11 Maintenance of the Chimney p 11 Instructions for user p 12 Fuel p 12 Lighting p 12 Air convection principle p 13 Operating procedure p 13 De ashing p 13 Clea...

Страница 21: ...x 277 x 250 Ash pan capacity litre 3 3 Weight kg 113 113 Heated volume m3 240 240 Firebox draught at maximum rate Pa 12 12 Firebox draught at minimum rate Pa 6 6 Flue mean gas flow g s 8 20 8 20 Flue...

Страница 22: ...ir collected at the bottom of the appliance spreads around the body where it becomes hot with the appliance wall radiation The hot air rising up goes to the room through the grille located in the hood...

Страница 23: ...ulation if the floor is combustible In all cases it is better to raise the height of the appliance to protect the floor of the heat radiation and allow fresh air required for the convection bellow the...

Страница 24: ...ion pipe and any draught stabiliser must have access for cleaning Foreseen an inspection trap 500 x 350 mm in the hood to allow access to the flue 6 Technical manual 1248 HEKLA ref 634 07 46 634 07 47...

Страница 25: ...ction X 530 from the stove to the small collar c If the floor of the hearth is rough place a metal plate to ease the setting of the insert fire in the chimney 634 07 46 only The fans must be plugged o...

Страница 26: ...Insulation 40 MM R 0 70 rockwool Internal diameter 200 MM Opening 100 X 100 MM Opening 200 X 500 MM Insulation 30 MM 1 wall R 0 80 Opening 100 X 100 MM Opening 200 X 200 MM of only wall Insulation 60...

Страница 27: ...tallation operations are completed fixing assembly etc Complies with Low tension Directive 73 23 CEE under standard NF EN60335 1 Electromagnetic compatibility Diretive 89 336 CEE The fans electrical r...

Страница 28: ...is possible to fit two outlets to diffuse air to adjacent rooms In this respect Remove the blanking plates on the casing on top of the appliance fig 13 Secure the 5 mm O D screws Fit the flue collars...

Страница 29: ...ting it 2 17 Maintenance of the Chimney Very important In order to avoid any incident chimney fire etc maintenance tasks must be carried out regularly If the appliance is regularly used the chimney sh...

Страница 30: ...ternal walls and the flue soot tar etc Recovered wood Railway sleepers telegraph poles offcuts of plywood or chip board pallets etc Burning treated wood quickly clogs the flue ways soot tar etc pollut...

Страница 31: ...and the flue pipe Open the door and remove all deposits in the firebox and clean the removable fire grate Cleaning of the glass door can be done with a soft cloth dampened with water and vinegar or po...

Страница 32: ...wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up The flue damper is closed Open the flue damper Flue duct is cold Burn paper and kindling wood to increase heat Room i...

Страница 33: ...Technical manual 1248 15 UHI 1RWH Note...

Страница 34: ...A 02 17 188814 Ceramic glass 504x315x4 A B 01 18 181632 Gasket 6 A B 1 m 19 200174 Base A B 01 20 217128 Shell A B 01 21 217231 Shell top A B 01 22 909818 Flue baffle A B 01 23 224046 Ash pan A B 01...

Страница 35: ...UWV 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 2 5 9 1 5 1 6...

Страница 36: ...or all appliances with the exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2...

Отзывы: