background image

2.9

Ceramic Fuelbed Layouts

Replacement coals and ceramic are available from your
dealer, but should be installed by acompetent person
(e.g. Corgi registered).
Please ensure that when fitting the matrix and coals,
that you

DO NOT OBSTRUCT THE PILOT FRANCO

BELGE

accept no responsibility for any injury sustained

whilst handling hot ceramics.

Instructions for the layout of the prefixed ceramic
matrix and loose coals for Belfort Flueless Stove.

Coal Layout

Parts : 1 Ceramic mat, 9 Ceramic coals.

-

Place the ceramic matrix on top of the ceramic mat, on
the top of the burner body.

-

Place 4 coals on top of the matrix as shown in (

A

).

-

Place the remaining 5 coals as shown in (

B

).

8

Technical manual “1183”

Belfort GP - ref. 154 05 16

Installation instructions

B

A

Содержание BELFORT GP 154 05 16

Страница 1: ...dress 2 rue Saint Gilles 68230 TURCKHEIM RC Colmar SIREN 439 330 325 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 43 Fax 00 333 28 43 43 99 Subject to...

Страница 2: ...tructions for user 10 Manual Tap 10 Recommandations 10 Safety devices 11 Maintenance 11 Trouble shooting 11 Spare parts 12 FRANCO BELGE congratulates you on your choice FRANCO BELGE which has been gra...

Страница 3: ...l be limited to the supply of the appliance 1 Description of the unit 1 1 Package The package will contain the following parts Belfort Stove inc Burner Logs kit FB 0516 or Coals kit FC 0516 1 2 Option...

Страница 4: ...se performance and safety Installation of your stove must comply with current building regulations Franco Belges therefore recommend that a CORGI engineer be employed for this task Taking particular n...

Страница 5: ...the stove The hearth must not be capable of inadvertent covering by a rug or carpet This may be achieved by either the hearth being 50 mm above the level of the floor or a fender or kerb around the he...

Страница 6: ...on to the stove or within 1 meter of the appliance An 8mm nut and olive is supplied with the stove for the final pipe joint A gas supply isolation tap must be installed in the supply pipework in a loc...

Страница 7: ...red with the appliance in the full rate position 2 8 Door Lock Technical manual 1183 7 Belfort GP ref 154 05 16 Installation instructions Figure 4 Door Lock 1 Safety screw 2 Male spanner 2 5 6 face 3...

Страница 8: ...sponsibility for any injury sustained whilst handling hot ceramics Instructions for the layout of the prefixed ceramic matrix and loose coals for Belfort Flueless Stove Coal Layout Parts 1 Ceramic mat...

Страница 9: ...ore the installed stove is left with the customer Carry out the test by first closing all doors and windows in the room containing the stove Ensure that the fire is burning at full rate for a minimum...

Страница 10: ...appliance is now burning at its highest operating output Running the appliance at low setting Ignite permanent pilot and run appliance at High setting for a minimum of 10 minutes as shown above With...

Страница 11: ...or performing correctly Ensure the pilot flame is the correct size for the type of gas The flame should be focused on the thermocouple probe The pilot flame will have been set correctly in the factor...

Страница 12: ...Top plate X 01 3 327801 00 Clamp X X X X X 01 4 303860 MK Flue collar X 01 4 303860 MP Flue collar X 01 4 303860 RH Flue collar X 01 4 303860 EF Flue collar X 01 4 303860 79 Flue collar X 01 5 306281...

Страница 13: ...902 EF Ash pan guide X 01 26 327902 79 Ash pan guide X 01 27 189713 Screw H M8X30 X X X X X 01 28 181632 Rope DIAM 6 X X X X X 0 90 m 29 181602 Ceramic rope DIAM 8 X X X X X 1 m 30 181614 Ceramic rope...

Страница 14: ...14 Technical manual 1183 Belfort GP ref 154 05 16 Spare parts 0 1 2 0 1 2 0 2 1 1 0 2 0 1 2 Figure 6 Spare parts view...

Страница 15: ......

Страница 16: ...of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in contact w...

Отзывы: