background image

USER’S MANUAL  

LOCAL PORTABLE AIR CONDITIONER

FRAL SUPER COOL FSC12H

PORTABLE AIR CONDITIONER

FRAL SUPER COOL

 

Mod. FSC12H

INST._PL_IT_EN_DE_FSC12H_WER.1

Содержание SUPER COOL

Страница 1: ...USER S MANUAL LOCAL PORTABLE AIR CONDITIONER FRAL SUPER COOL FSC12H PORTABLE AIR CONDITIONER FRAL SUPER COOL Mod FSC12H INST _PL_IT_EN_DE_FSC12H_WER 1...

Страница 2: ...er it has been shut down Otherwise the unit may sustain damage Do not turn on off the unit only by putting taking the plug in out of the socket Use the ON OFF button located at the unit s display The...

Страница 3: ...turn off the unit by pulling the power plug Warning Additional hazard is possible if the unit is used incorrectly Ensure your personnel is appropriately trained Warning The unit is not a toy and cann...

Страница 4: ...s warranty Make sure that hot air flows out freely from the outlet pipe Do not extend the hot air pipe beyond its maximum length of 2 metres If extended the unit s temperature cannot exceed 32 C Other...

Страница 5: ...mmend to attach the hot air pipe to the windowl window kit is available as an option Partially open the window and put in the window adapter vertically or horizontally Connect the pipe to the adapter...

Страница 6: ...adjusted CAUTION While operating as a drying unit the product does not provide cooling performance Do not connect the pipe when the unit is operated in drying mode The drying mode is recommended for...

Страница 7: ...ame time Do not put batteries in fire this may cause an explosion INFORMATION ON CORRECT DISPOSAL OF BATTERIES ACCORDING TO EUROPEAN DIRECTIVE 2006 66 EU and amendment of the Directive 2013 56 EU Repl...

Страница 8: ...N MODE INDICATOR VENTILATION TEMPERATURE AND TIME FEATURE INDICATOR SLEEP NIGHT MODE FAN OPERATION INDICATOR TEMPERATURE AND TIME DISPLAY FEATURE INDICATOR SWING FEATURE INDICATOR TIMER OPERATION MODE...

Страница 9: ...EEP mode cannot be started in the ven tilation mode TEMPERATURE AND TIME ADJUSTMENT BUTTON The temperature range is adjustable from 16 C to 30 C Temperature up 1 This allows to adjust temperature set...

Страница 10: ...cleaning it may damage its internal components or cause a short circuit Issue Error Cause Solution FL Water tank full Drain the tank If the error persists contact authorised repair service E1 Indoor...

Страница 11: ...ent temperature range cooling heating 7 35 C 7 35 C Refrigerant R290a 0 29 kg Noise level acoustic pressure 51 db A Dimensions W x D x H 470 x 382 x 770 mm Net weight 31 5 kg Safety standard CE Auto R...

Отзывы: