1.  SAFETY WARNINGS 

 

 

The  FDK100  Series  Dehumidifier  must  always  be  connected  using  the  grounded  electrical 
connection  as  required  from  all  electrical  appliances.    The  warranty  is  voided  and  all 
responsibility for the operation is born by the owner if non-grounded wiring is utilized. 

 

The FDK100 Dehumidifiers must only be maintained and serviced by a qualified technician. 

 

The FDK100 Dehumidifiers are intended only for operation when oriented with the unit sitting on 
its feet and level.  Any other orientation could cause water to come in contact with the electrical 
components.    Remove  plug  before  moving  dehumidifier.  If  any  water  may  have  spread 
throughout unit, the unit should be opened and allowed to dry thoroughly before reconnected to 
electric and restarting. 

 

For  proper  operation,  neither  the  inlet  or  discharge  should  be  positioned  against  a  wall.    The 
inlet requires a minimum of 12” clearance and the discharge needs a minimum of 24” clearance.   

 

For proper diffusion of air throughout the room, the dehumidifier should be  positioned  with the 
sides against a wall and the inlet and discharge perpendicular to the wall. 

 

Do  not  insert  any  objects  into  the  inlet  or  discharge.    If  service  is  required,  call  a  qualified 
technician.  All work on unit should be down with the unit “off” and unplugged. 

 

Do not use water to clean unit exterior.  Only use a damp cloth with unit unplugged. 

 

Do not use unit as shelf or device to hang clothes.  This could cause damage to unit. 

 

The inlet filter generally needs cleaned once per month.  Check unit on a weekly basis to ensure 
that more frequent cleaning is not required. 

 

Identification: 

 

For future reference, write down the model, serial number, date of purchase and use this information 
whenever corresponding concerning your dehumidifier. 

 

Model Number   

______________________ 

Serial Number _____________________________ 
Date of Purchase 

_____________________________ 

 
 

Warning 

115 Volts AC may cause serious injury from electric shock. 
 

1.  Disconnect electrical power before servicing 
2.  Plug unit only into grounded electrical outlet 
3.  Do not use extension cord 
4.  Do not use plug adapter 
 

Power Supply:

   

115V, 60 Hz 

 

 

 

 

AC Only 1 Phase 

Outlet Requirement:   

3-Prong 

Circuit Protector: 

 

Only compressor thermal and overload relay protector

 

 

Circuit Breaker                   Fuse on PCB supply 

 

 

Содержание FDKA100.1

Страница 1: ...M FDKA100 1 03 26 09 2017 DEUMIDIFICATORI DEHUMIDIFIERS FDKA100 1 MANUALE D USO E MANUTENZIONE USE AND MAINTENACE MANUAL M FDKA100 1 03 26 09 17...

Страница 2: ...should be positioned with the sides against a wall and the inlet and discharge perpendicular to the wall Do not insert any objects into the inlet or discharge If service is required call a qualified t...

Страница 3: ...to the room at a little bit higher temperature and lower Relative Humidity If the room temperature is lower than about 70 F the condensed moisture become ice In this case every roughly 30 minutes a de...

Страница 4: ...mply press the POWER key and depending on the relative humidity set the machine starts working When the machine reaches the level of required moisture goes into stand by mode automatically stops but r...

Страница 5: ...essary to make a cleaning of the warm heat exchanger condenser by using compressed air This operation must be done by a specialized technician This cleaning will improve the performances and the long...

Страница 6: ...arge a Confirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will for...

Страница 7: ...ard Defrosting Control System electronic Hot gas defrosting control system termost electronic Condensed Water Draining Pipe Connection 3 4 M Functioning Relative Humidity Range Temperature range 33 8...

Страница 8: ...R PURPLE ORANGE WHITE BROWN BLUE BLUE FAN SOLEDOID VALVE ELECTRICAL BRIDGE 2 ELECTRICAL BRIDGE 3 BLU BLUE R G A E V PUMP T1 T2 T3 0105 UR BLUE POWER SUPPLY 115V 60HZ PCB 115V 60HZ TRANSFORMER 115V 220...

Страница 9: ...a defect in workmanship or material These warranties do not apply for loss or damage caused by accident fire abuse misuse improper installation leaking modification misapplication weather freezing lac...

Страница 10: ...also have other rights which vary from state to state Some states do not allow limitations on warranties or on remedies for breach In such states the above limitations may not apply to you FOR CANADIA...

Страница 11: ...the unit to the condensate pump Dehumidifier Drain Fitting Level of Dehumidifier Drain Fitting drain drain Make sure no part of the hose is higher than the bottom of the drain fitting Note The drain...

Страница 12: ...tting IMPORTANT The drain hose from dehumidifier to pump must run downward and stay below the level of dehumidifier drain fitting Tubing line from pump can run up to 20 feet upward and out into drain...

Отзывы: