10

 

4.3.

 

ANTENNA FOOTPRINT 

This  antenna  footprint  applies  for  the  reference  evaluation  board  described  on  page  6  of  this 
User Manual. Feeding line dimensions over the clearance zone described in Figure 4 apply for 
a 1.0 mm thickness FR4 PCB. 
 

 

 

 

Measure 

mm 

7.0 

3.0 

1.5 

0.2 

2.6 

3.6 

3.0 

0.5 

4.7 

1.5 

Tolerance

: ±0.2mm

 

Figure 4 

 Antenna Footprint Details.

 

 

Other PCB form factors and configurations may require a different feeding configuration, feeding 
line dimensions and clearance areas. If you require support for the integration of the antenna in 
your design, please contact

 

[email protected]

 

 

 
 

5.

 

MATCHING NETWORK 

 
The  specs  of  a  Fractus  Antennas  standard  antenna  are  measured  in  their  evaluation  board, 
which  is  an  ideal  case.  In  a  real  design,  components  nearby  the  antenna,  LCD’s,  batteries, 
covers,  connectors,  etc  affect  the  antenna  performance.  This  is  the  reason  why  it  is  highly 
recommended placing pads compatible with 0402 and 0603 SMD components for a PI matching 
network as close as possible to the antenna feeding point. Do it in the ground plane area, not in 
the clearance area. This is a degree of freedom to tune the antenna once the design is finished 
and taking into account all elements of the system (batteries, displays, covers, etc). 

 

 

 

Содержание Compact Reach Xtend FR05-S1-N-0-102

Страница 1: ...ients develop innovative products and accelerate their time to market through our expertise in antenna design testing and manufacturing Compact Reach XtendTM FR05 S1 N 0 102 Some Fractus Antennas products are protected by Fractus patents All information contained within this document is property of Fractus Antennas and is subject to change without prior notice Information is provided as is and wit...

Страница 2: ... 0 102 Last updated on June 2017 2016 FRACTUS ANTENNAS S L 2 INDEX OF CHAPTERS 1 ANTENNA DESCRIPTION 4 2 QUICK REFERENCE GUIDE 4 3 ELECTRICAL PERFORMANCE 6 4 MECHANICAL CHARACTERISTICS 9 5 MATCHING NETWORK 10 6 ASSEMBLY PROCESS 11 7 PACKAGING 13 ...

Страница 3: ...CE GUIDE 4 3 ELECTRICAL PERFORMANCE 6 3 1 FRACTUS EVALUATION BOARD 6 3 2 VSWR AND EFFICIENCY 6 3 3 RADIATION PATTERNS GAIN AND EFFICIENCY 7 3 4 CAPABILITIES AND MEASUREMENT SYSTEMS 8 4 MECHANICAL CHARACTERISTICS 9 4 1 DIMENSIONS AND TOLERANCES 9 4 2 SPECIFICATIONS FOR THE INK 9 4 3 ANTENNA FOOTPRINT 10 5 MATCHING NETWORK 10 6 ASSEMBLY PROCESS 11 7 PACKAGING 13 ...

Страница 4: ...small consumer electronics devices such as wireless headsets and USB dongles TOP BOTTOM Material The Compact Reach XtendTM antenna is built on glass epoxy substrate APPLICATIONS Headsets Headphones Medical devices Modules WiFi Bluetooth Zigbee USB Dongles Sensors bike speed telemetry Military Digital cameras BENEFITS High efficiency and gain Cost effective Small footprint Easy to use pick and plac...

Страница 5: ...pact Reach XtendTM FR05 S1 N 0 102 Last updated on June 2017 2016 FRACTUS ANTENNAS S L 5 Please contact info fractusantennas com if you require additional information on antenna integration or optimization on your PCB ...

Страница 6: ...d in Figure 1 Tolerance 0 2mm Material The evaluation board is built on FR4 substrate Thickness is 1 0mm Measure mm A 41 0 B 23 0 C 47 0 D 8 0 E 26 0 Figure 1 Compact Reach Xtend TM Evaluation Board 3 2 VSWR AND EFFICIENCY VSWR Voltage Standing Wave Ratio and Total Efficiency versus Frequency GHz Figure 2 VSWR and Efficiency vs Frequency GHz SMA Connector Antenna Clearance Compact Reach Xtend Ante...

Страница 7: ...ut 0 Plane XZ Elevation Cut 90 Plane YZ Gain Peak Gain 1 7 dBi Average Gain across the band 1 2 dBi Gain Range across the band min max 0 7 1 7 dBi Efficiency Peak Efficiency 75 7 Average Efficiency across the band 72 2 Efficiency Range across the band min max 68 9 75 7 Table 2 Antenna Gain and Efficiency within the 2 4 2 5 GHz band Measures made in the evaluation board and in the Satimo STARGATE 3...

Страница 8: ...mize return on investment throughout the product development process We also provide our clients with the opportunity to leverage our in house testing and measurement facilities to obtain accurate results quickly and efficiently Agilent E5071B VSWR S Parameters Radiation Pattern Efficiency SATIMO STARGATE 32 Anechoic chambers and full equipped in house lab 2 2 5 3 3 5 4 4 5 5 5 5 6 20 18 16 14 12 ...

Страница 9: ...tes the feed pad Measure mm Measure mm A 7 0 0 2 E 1 1 0 1 B 3 0 0 2 F 2 2 0 1 C 2 0 0 2 G 4 0 0 2 D 0 4 0 15 Figure 3 Antenna Dimensions and Tolerances Fractus Compact Reach XtendTM chip antenna is compliant with the restriction of the use of hazardous substances RoHS The RoHS certificate can be downloaded from www fractusantennas com 4 2 SPECIFICATIONS FOR THE INK Next figure shows the correct c...

Страница 10: ... and clearance areas If you require support for the integration of the antenna in your design please contact info fractusantennas com 5 MATCHING NETWORK The specs of a Fractus Antennas standard antenna are measured in their evaluation board which is an ideal case In a real design components nearby the antenna LCD s batteries covers connectors etc affect the antenna performance This is the reason w...

Страница 11: ...e 12 3 After soldering the antenna to the circuit board perform a cleaning process to remove any residual flux Fractus Antennas recommends conducting a visual inspection after the cleaning process to verify that all reflux has been removed The drawing below shows the soldering details obtained after a correct assembly process Figure 6 Soldering Details NOTE Solder paste thickness after the assembl...

Страница 12: ... Free Assembly SnAgCu RAMP UP Avg Ramp up Rate Tsmax to Tp 3 ºC second max PREHEAT Temperature Min Tsmin Temperature Max Tsmax Time tsmin to tsmax 150 ºC 200 ºC 60 180 seconds REFLOW Temperature TL Total Time above TL tL 217 ºC 60 150 seconds PEAK Temperature Tp Time tp 260 ºC 20 40 seconds RAMP DOWN Rate 6 ºC second max Time from 25 ºC to Peak Temperature 8 minutes max Table 3 Recommended solderi...

Страница 13: ...in tape and reel packaging Measure mm W 16 0 0 3 A0 3 6 0 1 B0 7 5 0 1 K0 2 5 0 1 B1 8 1 0 1 D 1 55 0 05 D1 1 55 0 05 Wmax 16 3 E 1 7 0 1 F 7 5 0 1 K 2 8 0 1 P 8 0 0 1 P0 4 0 0 1 P2 2 0 0 1 Figure 8 Tape Dimensions and Tolerances Figure 9 Images of the tape Measure mm A max 330 0 1 0 G 17 5 0 2 t max 21 5 0 2 Reel Capacity 2500 antennas Figure 10 Reel Dimensions and Capacity ...

Отзывы: