Transport platform
SEP Serie
SEP u
ser’s manual Page 20 of 89
Doc no. RD-7243-MA-001-02
Description
Values
A
MAXIMUM
height of first (1)
mast anchor
20’-0” (6,0 m)
B
MAXIMUM
height of second
(2) mast anchor
«
R
EFER TO
YPICAL SPACING BETWEEN ANCHORS
),
ON
PAGE
C
Typical spacing between
anchors
«
R
EFER TO
(T
YPICAL SPACING BETWEEN ANCHORS
),
ON
PAGE
D
MAXIMUM
height of the
installation
1 300’-0” (400 m)
E
MAXIMUM
floor
height
17-
9/16” (450 mm)
F
MAXIMUM
height over the
last (highest) anchor
Ŧ At installation
: 0ft (0m) MAX above the roof of the platform to the last anchor
(position of anchor to install).
ŦŦ In operation
: 0ft (0m) MAX from the floor of the platform to the last anchor.
G
Spacing between anchors
MIN
29
”
MAX
50”
(0,73 m) (1,27m)
S
IMENSIONS AND ANCHOR FORCES DISTRIBUTION
ON PAGE
H
Distance between center of
the mast and face of
anchoring wall (length of
mast anchoring)
MIN
64,5
”
MAX
110
”
(1,65 m) (2,8 m)
S
IMENSIONS AND ANCHOR FORCES DISTRIBUTION
ON PAGE
*
J
Spacing between the
platform and the ground
protection mesh
* MIN
18”
MAX
80”
(0,45 mm) (2,0 m)
**
K
Height of the ground
protection mesh
** LOW MESH ** FULL HEIGHT
MIN
43” (1,10 m)
MIN
6’-6” (2,0m)
MAX moins de
6’-6” (2,0m)
.
***
L
Height of ground level door
*** LOW MESH *** FULL HEIGHT
MIN
43” (1,10 m)
MIN
6’-6” (2,0 m)
MAX
3’-11 1/4” (1,20m)
.
M
Height and spacing of cable
guides
MAX
20'-0
”
(6,0 m)
N
Clearance between platform
and power lines
Refer to effective local regulation
P
Distance between highest
anchor and end of mast
MIN
15'-3 5/8
” (4,66 m)
Table 7
– General dimensions
*
The
MIN
value 18" (0,45 m) may be reduced if
"K"
the height of the mesh is greater than 6'-6" (2,0 m).
**
Consider restrictions on the use of a
low mesh.
***
Consider restrictions on the use of a
low mesh.
Ŧ
Reference height during
installation
(assembly/disassembly).
ŦŦ
Reference height during
operation
(in use).