19
ENGLISH
AFC: “automatic frequency control” indicates the frequency deviation of the detector compared
to the wire radio interface module.
RESET (stat): it resets all the average values of all devices.
6 - RESET
There are two reset procedures of the MOD-WL16 named SOFT and HARD reset:
SOFT RESET:
reboots the interface without losing the settings. Press the RESET key for 3 se-
conds.
HARD RESET (RESET EEPROM):
the interface is reset to the factory default. Follow this pro-
cedure to delete all settings and acquired devices. Press the ACQ/DEF key first and then the
RESET key. Release the RESET key keeping the ACQ/DEF key pressed until the LED 3 flashes
three times.
To do hard reset:
-delete MOD-WL16 through aux. modules menu
-do the hard reset of MOD-WL16 (as described above)
-do the acquisition of MOD-WL16 through aux. modules menu
N.B: We recommend to reset the interface to the factory defaults when the interface is acquired
in another control unit.
7 - TECHNICAL SPECIFICATIONS
Voltage
8-14 V
Consumption @12V
55mA
Battery charge
75mA
Dimensions
99x80x30
Operating temperature
0°C - 40°C
INPUT
OUTPUT
PARTITION
MOD-WL16
KEYPAD 0
VARIOUS
EXCLUSIONS
TEST
READING
STATS
[device list]
RESET
MOD-WL16
RESET STAT?