Fraba UBIFAST Скачать руководство пользователя страница 4

Configure

 

▪  Pulses Per Revolution (PPR) –

 

Any value between 1 and 16384 pulses

 

▪  Incremental Pulse Direction – 

 

Choose „A before B“ or „B before A“ 
(Refer to encoder datasheet for more 
details)

 

▪  Incremental Output Driver – 

 

Choose the Incremental Output Driver

-

Push-Pull (HTL) / 4.75 - 30 V Supply 
Voltage,

 

RS422 (TTL) / 5 V Supply Voltage or

 

RS 422 (TTL) / 8-30 V Supply Voltage

Configure

 

▪  Pulses Per Revolution (PPR) 

 

Any value between 1 and 16384 pulses

 

▪  Incremental Pulse Direction  

 

Choose  „A before B“ or  „B before A“ 
(Refer to encoder datasheet for more 
details)

For Incremental encoders the following parameters are programmable:

For Hybrid (SSI + Incremental) the following parameters are 

 

programmable:

Step 1: Incremental Parameters (INC)

4

UBIFAST CONFIGURATION TOOL

INSTALLATION LeAFLeT

Содержание UBIFAST

Страница 1: ...e exit or to build your own connecting cables 12 VDC Power Adapter Input 100 to 240V AC 47 to 63Hz and interchangeable plugs for Europe UK US India Brazil China Argentina Australia Korea Safety Notes Recommended to use power adapter provided by POSITAL In case of replacement check for compatible supplies with same voltage and current rating 12 V 1 A Do not remove the Micro SD card or the Wi Fi USB...

Страница 2: ...tal M12 5 Pin 10028946 M12 8 Pin 10028947 M23 12 Pin 10030239 SSI Incremental M23 12 Pin 10026479 M23 16 Pin 10026481 All Terminal Block 10030474 Color State Description Yellow Solid Power to UBIFAST Tool is ON Yellow Blink UBIFAST Wi Fi Hotspot Ready Green Solid Programming of Device in Progress Pin No Wiring for SSI Incremental Wiring for Incremental 1 Data Do not connect 2 Clock Do not connect ...

Страница 3: ...ge will open and you can begin the configuration Note The UBIFAST Configuration Tool can be used to program both Incremental only and Hybrid SSI Incremental encoders The encoder type is automatically detected by the UBIFAST Configuration Tool and the programmable parameters in the subsequent steps are displayed accordingly The serial number SN of the encoder connected is always displayed on TOP of...

Страница 4: ...y Voltage RS422 TTL 5 V Supply Voltage or RS 422 TTL 8 30 V Supply Voltage Configure Pulses Per Revolution PPR Any value between 1 and 16384 pulses Incremental Pulse Direction Choose A before B or B before A Refer to encoder datasheet for more details For Incremental encoders the following parameters are programmable For Hybrid SSI Incremental the following parameters are programmable Step 1 Incre...

Страница 5: ...ion dependent on the configured resolution and number of turns Verify the Incremental and Absolute parameters to be configured Press Configure to start programming the encoder It is recommended to write the programmed parameters on the blank field provided on the encoder label Step 2 Absolute Parameters SSI parameters are programmable Step 3 Summary 5 UBIFAST CONFIGURATION TOOL Installation Leafle...

Страница 6: ...sources like LAN network or Cellular Data networks After 3 minutes of inactivity the UBIFAST box shall time out and the programming needs to be restarted from the beginning The message Session has timed out is displayed Only one user at a time can access the UBIFAST programming Interface Another user will see the message Device is used by another user If a user doesn t complete the programming ano...

Страница 7: ...Notes 7 UBIFAST CONFIGURATION TOOL Installation Leaflet ...

Страница 8: ...velopment engineers in Euro pe North America and Asia have direct responsibility for customer support In addition a growing global network of sales partners is providing expert guidance with knowledge about the local requirements Production POSITAL products are manufactured in advanced production facilities The computer guided semi automated pro duction system tracks each device from order through...