U32-4 FPI Direct Vent Gas Insert

IMPORTANT MESSAGE  

SAVE THESE 

INSTRUCTIONS

The FPI Gas Insert must be installed in 

 

accordance with these instructions. Carefully 
read all the instructions in this manual fi rst. 
Consult the building authority having jurisdiction 
to determine the need for a permit prior to starting 
the installation.

NOTE: 

 Failure to follow the instructions could 

cause a malfunction of the heater which could 
result in death, serious bodily injury, and/or 
property damage.  Failure to follow these 
instructions may also void your fi re insurance 
and/or warranty. 

FOR YOUR SAFETY

This appliance requires air for proper combustion.  
Always provide adequate combustion and 
ventilation air.  Follow instructions and 
information in CAN/CGA B149 (in Canada) or 
the National Fuel Gas Code ANSI Z223.1 (in the 
USA), regarding requirements for combustion 
and ventilation air.

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit 
must be disconnected.

Gas Input Capacity:

  

 Natural 

Gas 

30,000 

Btu/h

 Propane  30,000 

 

Btu/h

Min. Input

 

Natural Gas 

15,300    Btu/h

 Propane  15,000 

 

Btu/h

Fuels: 

 Approved for use with both natural gas, 

and propane. Approved as is for use at 0' to 
4,500' (0-1370m).

Electrical:

  120V   A.C. system.

Circulation Fan: 

 Variable speed, 110 CFM.

Log Set: 

 Ceramic fi bre, 7 per set.

Vent System:

   3" co-linear aluminum fl ex.

The effi ciency rating of the appliance is a 
product thermal effi ciency rating determined 
under continuous operating conditions and 
was determined independent of any installed 
system.

INSTALLATION

GAS PRESSURE 

TESTING

The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut off valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than
1/2 psig. (3.45 kPa).

INSTALLATION INTO A 

SOLID FUEL BURNING 

FIREPLACE OR 

FACTORY BUILT 

FIREPLACE

The U32-4 Gas Inserts have been tested and 
approved to be vented into any masonry fi replace 
or  approved solid fuel burning factory built 
fi replace that will allow the insert to physically 
fi t into the fi rebox. Refer to "Minimum  Fireplace 
Dimensions" section for minimum fi replace 
clearances.

If the factory built fi replace* height is too low for 
your Insert, you may remove the smoke baffl e 
plate, damper, refractory (fi rebricks), glass 
doors, screen rails, screen mesh and log grates 
from the factory built fi replace as long as these 
items are saved and are reinstalled in the event 
that the Insert is removed. 

Smoke shelves, shields and baffl es may be 
removed if attached by mechanical fasteners. 
If any part is removed it must not weaken the 
structural integrity of the factory built fi replace.

NOTE: Any alterations made to the listed solid 
fuel burning factory built fi replace may void the 
listing of the fi replace.

*Check with your local inspector before 
commencing with this installation.

BEFORE YOU START

Safe installation and operation of this appliance 
requires common sense, however,  we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:

General Safety Information

1)

  The appliance installation must conform 

with local codes or in the absence of local 
codes, with CAN/CGA B149 (in Canada) or 
the National Fuel Gas Code ANSI Z223.1 in 
the U.S.A. This appliance should be installed 
by a qualifi ed gas fi tter technician only.

2)  Installation and repair should be done 

by a qualifi ed service person.  

3)

  The  appliance should be inspected before 

use and at least annually by a professional 
service person. More frequent cleaning 
may be required due to excessive lint from 
carpeting, bedding material, animal hair, etc.  
It is imperative that control compartments, 
burners and circulating air passageways of 
the appliance be kept clean. 

4)

  See general construction and assembly 

instructions. This appliance may only be 
installed in a vented, noncombustible 
fi replace.

5)

  This appliance is Listed for bedroom 

 

installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.

6)

  Always connect this insert to a vent system 

venting to the outside of the building 
envelope. Never vent  to another room or 
inside a building.  Make sure that the vent 
is properly sized and is of adequate height 
to provide the proper draft.  

7)

  Inspect the venting system annually for 

blockage and any signs of deterioration.   

8)

  Any glass removed for servicing must be 

replaced prior to operating the appliance.  

9)

  To prevent  injury, do not allow anyone who 

is unfamiliar with the operation to use the 
fi replace.  

10) 

Due to high temperatures, the appliance 
should be located out of high traffi c areas 
and away from furniture and draperies. 
Children and adults should be alerted to 
the hazards of high surface temperatures, 
especially the fi replace glass and gold 
trims, and should stay away to avoid burns 
or clothing ignition. Young children should 
be carefully  supervised when they are in 
the same room as the appliance. Clothing 
or other fl ammable material should not be 
placed on or near the appliance.

Emissions from burning  wood or gas could 
contain chemicals known to the State of 
California to  cause cancer, birth defects or 
other reproductive harm.

Installer must mechanically attach the supplied 
label to the inside of the fi rebox of the fi replace 
into which the gas fi replace insert is installed.

"

WARNING

: This fi replace has been converted 

for use with a gas fi replace insert only and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."

Содержание U32-LP4

Страница 1: ...ce Installation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch a...

Страница 2: ...ry equipped with a means to secure the unit INFORMATION FOR MOBILE MANUFACTURED HOMES AFTER FIRST SALE This FPI product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to th...

Страница 3: ...fety 6 Speci cations 6 Gas Pressure Testing 6 Installation Into A Solid Fuel Burning Fireplace Or Factory Built Fireplace 6 Before You Start 6 Installation Checklist 7 Manufactured Mobile Home Additio...

Страница 4: ...fference the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the Sta...

Страница 5: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY...

Страница 6: ...urning factory built replace may void the listing of the replace Check with your local inspector before commencing with this installation BEFORE YOU START Safe installation and operation of this appli...

Страница 7: ...7 Test gas pressure Refer to section Gas Pipe Pressure Testing Check aeration system Refertosection GasInsertAeration System 8 Installstandardandoptionalfeatures Refer to the following sections a Bri...

Страница 8: ...is inlet hole 3 Locate the center point where the vent will pass through the chimney above the appliance Move the appliance into the exact location where it is to be installed Ensure that the Insert i...

Страница 9: ...t you can slide the brick tabs on to the screws easily but that the tabs are secure For the location of the side brick tab screws see diagram 1 5 Remove the brick tabs and slide the side brick panels...

Страница 10: ...Left Log C 02 56 on the two pins as shown F 02 48 B 02 45 E 0 2 4 7 INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the...

Страница 11: ...nect the fan switch wires by taking the black and red wires with the male ends in the grey harness and connect them with the wire connectors from the fan speed control 6 Connect the ON OFF switch wire...

Страница 12: ...s with a black frame To install the frame simply hook the top door ange onto the top of the unit and swing the door towards the unit diagram 1 Be careful that the glass gasket does not roll up there m...

Страница 13: ...n the unit Hook the top of the bay door over the ush door ange and swing the bottom against the bottom ange of the ush door Press down on the Bay Bottom bracket and push in until it clips behind the b...

Страница 14: ...n Sheet 5 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out DC Sparker Kit Contains Qty Part Description 1 820 475 Bracket DC Sparke...

Страница 15: ...nnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker Piezo Ignitor Ignitor Wire Piezo Ignitor Ignitor Wire DC Sparker 24 Install the 3 4 nylon plug to cover up the hole on th...

Страница 16: ...oper flame appearance and glow on logs NOTE The battery in the DC Sparker Box will need to be replaced an nually 25 Connect the DC spark generator wires to the SIT Valve with the screw which is provid...

Страница 17: ...to side trim 2 Lift unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit Unit should touch tabs on Bottom Trim Bracket Bottom Trim Bracket Push in Corners 3 Co...

Страница 18: ...Top Frame is held in place by friction t if the frame needs to be adjusted bend the bracket accordingly Hinge Screen Door 7 Install the Left and Right Side Screen Doors in the fully open position by p...

Страница 19: ...ace the switch box assembly over the boss on the rear left side piece and secure with one screw 28 9 Tuck the wires into the faceplate to keep them away from the insert using the clip provided Attach...

Страница 20: ...to place Slide side ller bracket into gap between glass and re box Side Hook Slots 12 To put on the Hampton logo peel the sticker from the back of the logo and place it centered on the bottom left han...

Страница 21: ...y harness and connect them with the wire connectors from the fan speed control Connect the ON OFF switch wires by taking the black and red wires with the female ends and connect them to the ON OFF swi...

Страница 22: ...the 6 screws provided Left Side Door Pin on Door Frame Note If you nd that the Left or Right Side Screen Door is lower then the other use the spacer provided to help align the Doors The spacer is to b...

Страница 23: ...ontrol wires for to the 120V wires 3 Install3AAAalkalinebatteriesintransmitter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiver to...

Страница 24: ...a power failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wi...

Страница 25: ...25 U32 4 FPI Direct Vent Gas Insert For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this manual INSTALLATION...

Страница 26: ...ly push and release the black button on spark igniter until pilot lights Continue to hold the control knob in for approximately one minute then release the gas control knob The pilot ame should contin...

Страница 27: ...nute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 3 and 4 If knob does not pop up when released stop and immediately call your servic...

Страница 28: ...nder warranty GLASS GASKET If the glass gasket requires replacement use glass gasket Part 936 265 for the Bay Front and a tadpole gasket for the Flush Front Part 936 155 Top View of pilot ame Top View...

Страница 29: ...rebox wall and lift out 8 Remove the 10 screws holding the Access Panel in place 9 Remove the Fan Air Duct by loosening the 3 screws squeeze the sides together to remove TO REMOVE FAN 1 Turn the unit...

Страница 30: ...ng 13 Fire up the unit temporarily and check the manifold pressure 14 Reinstallthevermiculite embers rockwool logs and brick panels as needed 15 Close the door and replace the louvers 16 Fire up the u...

Страница 31: ...lush Louvers Set Black 420 923 FlushLouvers Set Black Steel 25 420 940 Bay Louvers Set Black Gold 420 938 Bay Louvers Set Black 420 942 Bay Louver Set Black Steel 422 901 BrickPanelSet StandardBrown 4...

Страница 32: ...7 904 390 Burner Ori ce LP 52 936 170 Ori ce Gasket 66 910 038 Pilot Assembly 3 Flame NG 910 039 Pilot Assembly 3 Flame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 402 935 Log Set 402 572 E...

Страница 33: ...oor Trim 112 904 196 1 Round Magnet 910 421 PilotOn Off3 ExtensionKnob SIT 910 422 FlameHi Low3 ExtensionKnob SIT 402 956 Gold Trim Bay Front 402 958 Steel Trim Bay Front Not available as a replacemen...

Страница 34: ...Side Left Custom 74 904 586 Speed Control Knob c w Spring Clip FACEPLATE ASSEMBLY Part Description Part Description 402 918 Complete Faceplate Set Standard Contour with Black Trim 91 Faceplate Side Ri...

Страница 35: ...Knob Black Cast Surround 201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 Mounting Flange 195 Hampton Logo Plate 207 402 981 Cast Grill Set Top Bottom...

Страница 36: ...________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________...

Страница 37: ...________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________...

Страница 38: ...________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________...

Страница 39: ...ed by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replaceme...

Страница 40: ...da FPI Regency Hampton and Palace are trademarks of FPI Fireplace Products International FPI replaces are designed with reliability and simplicity in mind In addition our internal Quality Assurance Te...

Отзывы: