background image

Introduction

This manual is designed for the home owner in conjunction with the technical manual.

 *

R

ating

 L

abeL

 L

ocation

:

The rating label is located on the inside of the rear hopper access cover.

F

ueL

 Q

uaLity

:

Fuel quality is important, please read the following:
Your Hampton pellet stove has been designed to burn ¼” (6mm) dia wood pellets and other 

organic pellet fuels (corn, wheat, barley). DO NOT use this appliance as an incinerator. DO 

NOT use unsuitable and non recommended fuels, including liquid fuels as this will void any 

warranties stated in this manual. 
The performance of your pellet stove is greatly affected by the type and quality of fuel being 

burned. As the heat output of various quality fuels differs, so will the performance and heat 

output of the pellet stove.
CAUTION:

 It is important to select and use only fuel that are dry and free of dirt or any impurities 

such as high salt content. Dirty fuel will adversely affect the operation and performance of the unit 

and will void the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet 

manufacturers. We recommend the use of pellets that meet or exceed these standards. Ask your dealer 

for a recommended pellet type.

ASH

: The ash content of the fuel and operation of your stove will directly determine the frequency of 

cleaning. The use of high ash fuels may result in the stove needing to be cleaned daily.  A low ash fuel 

may allow longer intervals between cleaning.

CLINKERING:

 [clinkers are silica (sand) or other impurities in the fuel that will form a hard mass during 

the burning process]. This hard mass will block the air flow through the Burn Pot Liner and affect the 

performance of the stove. Any fuel, even approved types, may clinker.  Check the Burn-Pot Liner daily to 

ensure that the holes are not blocked with clinkers. If they become blocked, remove the liner (when the 

unit is cold) and clean/scrape the clinkers out.  Clean the holes with a small pointed object if required.  

Refer to the section Routine Cleaning and Maintenance. 

FUEL FEED RATES:

 Due to different fuel densities and sizes, fuel feed rates may vary.  This may require 

an adjustment to the slider damper setting or to the auger feed trim setting.
Since Regency Fireplace Products Ltd. has no control over the quality of fuel that you use, we assume no 

liability for your choice in fuels.

FILLING FUEL HOPPER

: Open lid on top of unit, check hopper for foreign objects, empty the bag into 

the hopper, and ensure hopper lid closes completely.

Store fuels in a dry location at least 36” (1 m) away from the pellet stove, and clear of the 

space required for charging and ash removal.  

WARNING: Parts of the appliance, especially the external surfaces, will be hot to touch 

when in operation so use due care.
FLAMMABLE LIQUIDS:

 

Never 

use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter 

fluid, or similar liquids to start or “freshen up” a fire in the heater.  Keep all such liquids well away from 

the heater while it is in use.

Hampton GC60 Cast Pellet Stove Owner’s Manual

4

Содержание Hampton Greenfire GC60

Страница 1: ...ne or other flammable vapoursandliquidsinthevicinityofthisoranyother appliance Installation and service must be performed by an authorized installer or service agency Tested by IMPORTANT SAVE THESE IN...

Страница 2: ...ency s wood emission limits for wood emission limits sold after May 15 2015 Under specific test condition this heater has been shown to deliver heat at rates raging from 9200 45 500 Btu hr Efficiency...

Страница 3: ...uctions 6 Dimensions Specifications 6 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 7 Turning Your Pellet Stove Off 9 Slider Damper Set Up 9 Ro...

Страница 4: ...l may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the burning process This hard mass will block the ai...

Страница 5: ...or and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation of the pellet stove Also ensure all gaskets on the door are checked and r...

Страница 6: ...ruction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS...

Страница 7: ...ge Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 60 lb 36 3 Kg 1 5 lb hr 0 68 Kg hr Testing Standard Weight with full hopper Consumption on Hi...

Страница 8: ...row to adjust setting 3 Light is the default setting Depending on Fuel quality Ignition problems may occur at higher altitudes this can be resolved by trimming the Combustion Fan to a higher setting 7...

Страница 9: ...en pressed After the ten 10 minutes it will pulse at the same interval as the feed auger When the start up sequence is complete the unit will ramp up in two 2 minute intervals until it has reached the...

Страница 10: ...a negative pressure range of 0 15 0 17 inches of water column 37 42 Pa This can be measured using a Magnahelic pressure gauge once the unit has been running on heat level 5 setting after one hour of b...

Страница 11: ...locks at the right rotate the top of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner out of the stove 5 L...

Страница 12: ...gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airtight assembly ASH BOX...

Страница 13: ...otection It is very important that the stove be cleaned and serviced as stated above CLEANING PAINTED SURFACES Please clean surfaces with a soft damp cloth CLEANING ENAMEL SURFACES Enamel Finishes and...

Страница 14: ...r the first two 2 years and limited labour for the first two 2 years to the original purchaser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to th...

Страница 15: ...aler before installation 10 FPI will not be responsible for inadequate performance caused by environmental conditions 11 The Limited Warranty does not cover installation and operational related proble...

Страница 16: ...n any stove replaced in field and is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required by the A...

Страница 17: ..._________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________...

Страница 18: ..._________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________...

Страница 19: ..._________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________...

Страница 20: ...______ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed ________________________________________...

Отзывы: