SPECIFICATIONS 

 

Mechanical 

AMBIENT CABINETS 

 - 

SPECIFICATIONS 

 
 

 

CABINET MODEL 

 

IN 3A06 

IN 3A08 

IN 3A12 

IN 3A15 

Height 

767 mm 

761 mm 

761 mm 

761 mm 

Width 

593 mm 

803 mm 

1203 mm 

1503 mm 

Depth 

663 mm 

663 mm 

663 mm 

663 mm 

Dry Weight 

55 kg 

55 kg 

70 kg 

81 kg 

Cabinet Well Material 

Stainless steel 

Cabinet Colour 

Grey, stainless steel and natural anodised aluminium.

 

Top Lighting 

Standard 

Shelf Lighting 

Optional 

Glass Type 

Toughened 

Glass (front/back) 

Single glazed 

Glass (ends) 

Double glazed 

Front Doors 

Sliding or Fixed options 

Number of Shelves 

Three plus base 

Display Area 

0.7 m

2

 

0.9 m

2

 

1.4 m

2

 

1.8 m

2

 

Climatic Class & IP 

Cabinets are tested under Climate Class 3 conditions and have IP 20 ratings 

 

 
Electrical 

AMBIENT CABINETS 

 - 

SPECIFICATIONS 

 
 

 

CABINET MODEL 

 

IN 3A06 

IN 3A08 

IN 3A12 

IN 3A15 

Voltage 

220 - 240 V   50 Hz   1

 

Power (with shelf lights) 

25 W 

36 W 

48 W 

72 W 

Current (with shelf lights) 

0.11 A 

0.15 A 

0.20 A 

0.31 A 

Connection 

3 pin plug, 10 A lead 

Temperature Range 

Room Temp 

Top Lights 

1 x LED strip 

1 x LED strip 

1 x LED strip 

1 x LED strip 

Optional Shelf Lights 

2 x LED strips 

3 x LED strips 

3 x LED strips 

3 x LED strips 

 
 

 

Содержание IN 3A06

Страница 1: ...Ambient Cabinets Curved Format...

Страница 2: ...uture Products Group Limited All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopyin...

Страница 3: ...ution 7 OPERATION 8 Cabinet Layout 8 3000 Series Cabinets 8 Lighting 8 Controls 8 Light Switch 8 Preparation 9 Shelf Location and Ticketing 9 Shelf Adjustment 9 Power Supply 9 Load Cabinet 9 Turn on L...

Страница 4: ...tion 15 Location 15 Ventilation 15 Access 15 Fumes and Odours 15 Livery 16 Custom Inserts 16 SERVICING 17 Control Gear 17 Location 17 Lighting 17 Caution 17 Test Lighting Components 17 Access to LED S...

Страница 5: ...S 21 Model IN 3A06 21 Model IN 3A08 21 Model IN 3A12 22 Model IN 3A15 22 SPARE PARTS 23 Cabinet Serial Number 23 MECHANICAL DRAWINGS 25 Dimensions 25 IN 3A06 25 IN 3A08 12 15 26 Cabinet Variants 27 Li...

Страница 6: ...w its recommendations The time taken will be well spent These instructions both general and technical tell you how to install operate and look after your inline food service cabinet so that you can re...

Страница 7: ...ge or malfunction resulting from the use of non FPG supplied spare parts Specific Exclusions The following are specifically excluded from warranty Breakage of glass or plastic components or the replac...

Страница 8: ...d rear doors The series includes Ambient Heated and Refrigerated models The cabinet lighting controls are on the back of the cabinet Lighting All cabinets are fitted with high efficiency LED lighting...

Страница 9: ...one on each bracket lift the brackets straight up firmly and then pull the brackets forward to disengage them from the slots in the support posts Insert the brackets into their new position and push b...

Страница 10: ...eady for service turn on the cabinet lights Ventilation The cabinet is ventilated via louvers in the control panel above the rear doors If the louvers are blocked heat from the lights will raise the i...

Страница 11: ...fuses on Internal fuse blown Have wiring checked and replace fuse 5A Slow Blow Cabinet Temperature High Ventilation louvers blocked Clean to remove blockage Extractor fan failed 600 only Replace fan C...

Страница 12: ...el and aluminium surfaces will be damaged Glass All glass should be cleaned using a good quality glass cleaner and a clean cloth Do NOT clean glass with abrasive pads or cleaners e g Scotchbrite pads...

Страница 13: ...sher detergents will damage any anodised aluminium parts Routines AMBIENT CABINETS CLEANING Schedules To maintain optimum performance cleaning schedules must be regular and thorough Inspection As part...

Страница 14: ...r supplier The cabinet is supplied fully assembled but the shelf trays are packed separately Site Preparation Ensure the cabinet location and any bench cut outs are made to the precise measurements sh...

Страница 15: ...the cabinet Isolation If the cabinet is not connected by a plug and socket but is hard wired to the mains supply a means of isolation must be provided If a plug and socket are used they should still b...

Страница 16: ...ttom one The lower strip is held captive by the cabinet ends and has to be bowed for removal and insertion Insert the upper edge into the narrow groove closest to the curved surface bow the strip to i...

Страница 17: ...D strip check that its power supply is working If there is no dc voltage at the output the power supply should be replaced If there is a dc output the LED strip must be replaced Access to LED Strips T...

Страница 18: ...ors Each sliding door has a seal between the door and the cabinet end panel The seal slides into a groove in the door extrusion and can be withdrawn and replaced if damaged A centre seal is fitted bet...

Страница 19: ...ack Single glazed Glass ends Double glazed Front Doors Sliding or Fixed options Number of Shelves Three plus base Display Area 0 7 m2 0 9 m2 1 4 m2 1 8 m2 Climatic Class IP Cabinets are tested under C...

Страница 20: ...AS NZS CISPR and BS EN 55014 1 Essential safety requirements AS NZS 3820 and AS NZS 4417 Energy efficiency for refrigerated appliances MEPS Australia New Zealand Please contact FPG to discuss your re...

Страница 21: ...IN 3A06 08 12 15 21 Future Products Group ELECTRICAL CIRCUIT DIAGRAMS Model IN 3A06 Inline 3000 Series 600mm Ambient Cabinet Model IN 3A08 Inline 3000 Series 800mm Ambient Cabinet...

Страница 22: ...26117 Rev F September 2018 22 Inline 3000 Series Cabinets ELECTRICAL CIRCUIT DIAGRAMS Continued Model IN 3A12 Inline 3000 Series 1200mm Ambient Cabinet Model IN 3A15 Inline 3000 Series 1500mm Ambient...

Страница 23: ...GO 14372 Knob light switch 14374 Fuse Link 5A 250V Slow Blow 13330 Ant surge Thermistor 10 Ohm 3A 22354 24V 60W LED power supply 21613 36V 100W LED power supply 25922 LED Driver 700mA 25762 Polycarbon...

Страница 24: ...ng Door 1200 cabinets only 62664 Back Outer Sliding Door 1200 cabinets only 62665 Back Inner Sliding Door 1500 cabinets only 62666 Back Outer Sliding Door 1500 cabinets only 62667 Front Inner Curved S...

Страница 25: ...IN 3A06 08 12 15 25 Future Products Group MECHANICAL DRAWINGS Dimensions AMBIENT CABINETS MECHANICAL DRAWINGS IN 3A06...

Страница 26: ...Part No 26117 Rev F September 2018 26 Inline 3000 Series Cabinets Dimensions cont AMBIENT CABINETS MECHANICAL DRAWINGS IN 3A08 12 15...

Страница 27: ...ANICAL DRAWINGS Cabinet Variants The drawings show the common overall dimensions for 800mm 1200mm and 1500mm cabinets The cabinets can have a single fixed front glass in place of the twin sliding door...

Страница 28: ...ounting The following diagram shows the aperture dimensions which will allow the cabinet well to enter the bench The cabinet deck trays will then be just above bench height On Bench Mounting The follo...

Страница 29: ...IN 3A06 08 12 15 29 Future Products Group...

Страница 30: ...Part No 26117 Rev F September 2018 30 Inline 3000 Series Cabinets...

Страница 31: ...IN 3A06 08 12 15 31 Future Products Group...

Страница 32: ...to change specifications and design without notice AUSTRALIA E ausales fpgworld com T 1800 813 745 CHINA ASIA E asales fpgworld com T 86 21 3351 3390 EUROPE E eusales fpgworld com T 31 6 5253 4769 IND...

Отзывы: