FPC SureBonder 9600A Скачать руководство пользователя страница 3

Preparing for Use

 

 

 

 

     

 

 

       

 

 

 

     

   

If stapler has been stored in a cold environment, bring it to a warm area and allow it to warm up

 

before using.

Loading Staples 

 

 

 

   

 

 

 

  

- Make sure Stapler is disconnected from Air Supply.

 

 

 

 

 

 

 

   

 

 

 

   

 

 

- Only use the proper size and type of staple with this stapler, as specified under "Staples".

 

 

 

 

 

   

 

 

 

 

 

 

 

- Depress the Track Release Lever to release the spring-loaded Staple Magazine; slide the

 

 

         

 

magazine out (back) as far as it will go.

 

   

 

 

 

 

TO LOAD STAPLES-TURN STAPLER UPSIDE DOWN,

insert a full strip of staples into the staple

 

 

 

 

 

  

 

 

 

 

 

 

 

 

magazine with the staple points facing up (Fig. 1). Slide the staple magazine closed until the track

 

 

 

 

 

 

 

 

 

 

 

release lever clicks back in place.  (Closing the staple magazine while staples are loaded engages

 

 

     

 

 

 

 

   

 

 

 

the spring-load mechanism, so it will take slightly more pressure to slide the magazine closed).

Using the Stapler

 

 

   

 

   

 

 

 

 

 

 

 

 

 

 

- This stapler is equipped with a contact safety mechanism; the stapler will not operate unless the

 

   

 

 

 

 

     

contact mechanism is firmly depressed against the surface to be stapled.

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

- Grip the body of the stapler firmly, make sure that the contact mechanism is placed securely

 

 

 

 

 

 

   

   

  

against work surface, and pull the trigger to drive a staple.

 

 

 

 

 

- Remove finger from the trigger.

   

 

 

 

 

 

   

 

   

 

     

 

 

 

- To drive another staple, move the stapler to next area on work surface to be stapled, and repeat

 

these steps.

Bump Fire Stapling: 

Keep the trigger pulled when moving across the work surface with a “bump” 

motion and depress the contact mechanism to drive staples in succession. 

After Stapling

 

 

   

 

 

 

- Disconnect the air hose from the stapler.

 

   

 

 

 

 

   

 

- Remove all staples from the staple magazine of the stapler.

 

 

 

     

   

 

 

 

- Place several drops of oil (included in case) into the air inlet.

 

     

 

 

 

 

 

 

 

 

- Shut off air compressor and drain any moisture from the compressor tank.

 

 

   

 

 

 

 

 

 

 

     

 

   

 

 

- Drain the air line filter; clean the filter element, then blow air in opposite direction to remove any    

dirt/debris.

 

 

 

 

   

   

- Keep lubricator filled with oil (included in case).

Clearing Staple Jams

 

 

   

 

 

 

- Disconnect the air hose from the stapler.
- Unscrew 4 nosepiece screws to release nosepiece (Fig. 2).

 

 

 

 

 

 

 

- Clean and carefully remove staple strip from staple magazine.

 

 

 

 

 

 

 

 

 

- Remove any remaining loose staples from inside the

 

 

 

   

 

 

   

staple magazine, using pliers to grasp the staples, if necessary.

 

 

 

 

 

 

 

 

 

- Once jammed staples have been removed, reload stapler.

APPLICATIONS

Including, but not limited to: insulation, roofing felt, house wrap, auto and marine vinyl trim, 

cabinet felt, cabinet backs, screen door repair, small furniture, light trim, molding and picture 

frames, and general staple use.

FEATURES

- View window for staples

- Adjustable exhaust

- Rubber hand grip for comfort

- Bump Fire Operation

- Firing Safety mechanism

- Easy drop-in staple loading

STAPLES

The Surebonder 9600A Pneumatic Stapler is designed to use a 20 gauge, narrow crown, 

heavy-duty wire staple in 1/4", 5/16", 3/8", 1/2", 17/32" and 9/16" leg lengths. 

For best results use: 

Surebonder #4 Heavy-Duty Staples

 

(same as Arrow T50 or Stanley TRA700 Series Staples). 

AIR SUPPLY

This stapler is designed to operate on clean, dry, regulated compressed air, between 

60 and 

100 psi. (Do not exceed 100 psi).

 It is preferable to include an air filter, pressure regulator, 

and automatic oiler within 15 feet of the tool, if possible.

An air filter is needed to remove contaminates and moisture that are contained in compressed 

air; filtering will significantly prolong the life of the tool.  If an automatic oiler is not installed,

 

place 5 to 6 drops of oil into the tool's air inlet at the beginning of each work day and 

2 to 3 drops of oil after using approximately 3 strips of staples. 

The staple gun comes factory-equipped with a male quick connector.  The staple gun must 

always be connected to the air supply with a coupling that removes all pressure when it is 

disconnected.

NOTE:  all components used with this staple gun (air hose, connectors, regulators, 

filters, etc) must be rated at 150 psi, OR 150% of the maximum compressor 

potential, whichever is higher.  Do not connect this staple gun to a system with 

maximum potential air pressure greater than 200 psi.

AIR CONNECTION SETUP

20

0

40

60

80 100

120

140

160

Lubricator             Regulator                Filter

To compressor

To Air Tool

Quick Connector   Quick Coupler

Fig. 1

LOADING STAPLES:

 

Turn stapler upside down,

insert a full strip of staples into staple magazine with 

staple points facing up.

 (see diagram)

Insert staple points facing up!

Unscrew 4 nosepiece screws 

to release nosepiece.

Fig. 1

Fig. 2:

4

3

Отзывы: