FP-TECH FP-619 Скачать руководство пользователя страница 3

Door Station

2-wire Door Station

Quick Installation Guide

Please read this manual carefully before using the product .

01

01

03

03

04

04

02

02

01

01

03

03

02

02

01

01

02

02

01

01

01

01

02

01

17

18

20

19

23

24

22

21

15

16

14

13

11

12

10

09

05

06

08

07

03

04

02

01

07

08

06

05

01

02

04

03

27

28

26

25

Dimension: 195(H)

×

130(W)

×

52(D)mm            

Embedded Dimension: 185(H)

×

110(W)

×

33(D)mm

Dimension: 276(H)

×

130(W)

×

52(D)mm            

Embedded Dimension: 270(H)

×

108(W)

×

33(D)mm

Dimension: 360(H)

×

130(W)

×

52(D)mm            

Embedded Dimension: 350(H)

×

110(W)

×

33(D)mm

9. Specification

Ÿ

Power supply:  DC 24V

Ÿ

Power Consumption:  1W in standby, 5W in working

Ÿ

Unlock Power output: 12Vdc, 250mA

Ÿ

Unlock timing: 1s, 5s, 10s, 15s

Ÿ

Working Temperature:  -20

~ +55

-5-

6. DIP

 

Switches

 

Settings

Total 6 bits in the DIP switches can be configured. The switches can be modified either 

before or after installation.

1 2 3 4 5 6

ON

DIP

ON

ON

ON (1)

OFF (0)

=

=

Bit-1

,

Bit-2

 

and

 

Bit

-

3 are used for door station ID setting(1=on,0=off).

Bit-1

,

Bit-2

 

and

 

Bit

-

3 are used for door station ID setting(1=on,0=off). 

000

 - 

100

 - 

010

 - 

110

 - 

001

 - 

101

 - 

011

 - 

111

000

 - 

First

 

door

 

station

100

 

Second

 

door

 

station

010

 - 

Third

 

door

 

station

110

 - 

Fourth

 

door

 

station

If

 

there

'

s

 

extra

 

camera

 

connected

 

with

 

the

 

system

The

 

door

 

station

 

ID

 

 

would

 

be

 

000 - First door station

010

 - 

Second

 

door

 

station

001

 -  

Third

 

door

 

station

011

 - 

Fourth

 

door

 

station

Bit-4 and Bit-5 is used for unlock time setting. 

00 - 1

 

second

 (

Default

 

setting

)

10

 - 

5

 

seconds

01

 - 

10

 

seconds

11

 - 

15

 

seconds

Bit

-

6

 

is

 

used

 

for

 

connecting

 

extra

 

camera

.

0

 - 

No

 

extra

 

camera

 (

Default

 

setting

)

1

 - 

Connecting

  

with

 

extra

 

camera

-4-

7. Electric Lock Connection

12V 300mA

+

-

Jumper position in 2-3

NO NC COM GND GND OPEN

CN3

Exit button

12V 300mA

+

-

Jumper position in 1-2

NO NC COM GND GND OPEN

CN3

Exit button

*Revision: PL161226

Power ON to open 

Power on to unlock type

1. The door lock power for a 12v DC strike (max current=250mA).
2. Set the jumper SIP1 set to 1-2 for a normally closed lock (power OFF to open), or set SIP1 
to 2-3 for a normally open lock(power ON to open.
3. Adjust the timer setting with Bit-4 and Bit-5 at the outdoor station
(1=on,0=off)
00-1sec, 01-5sec,10-10sec,11-15sec

8. Electric Lock Connection

1. The external power supply must be used according to the lock.
2. The jumper must be taken off before connecting.
3. If different unlocking time is needed, change the unlock time on door station by 

modifying the BIT-4 and BIT-5.

+

-

Take off the jumper

NO NC COM GND GND OPEN

CN3

1 2 3

SIP1

Exit button

-

+

+

-

Take off the jumper

NO NC COM GND GND OPEN

CN3

1 2 3

SIP1

Exit button

-

+

Power off to unlock type

Power off to unlock type

1 2 3

SIP1

1 2 3

SIP1

01

02

04

03

07

08

06

05

03

02

01

09

10

12

11

15

16

14

13

19

20

18

17

03

04

02

01

1) 

Make a master card

    Firstly to cut off the power of the outdoor station, secondly to connect JP2 with power, then 

sound will be heard every 1.5second,now to swipe new ID card will hear a long beep, that means 

new master card has been made,finally to take off JP2 will exit.

2) 

Delete all user cards

    Firstly to cut off the power of the outdoor station, then to connect JP3 with power,now a long 

beep will be heard, that means all user cards has been deleted, finally to take off JP3 will exit.

3) 

:

Add more user ID card

     Under standby,firstly to swipe the Master card, then to swipe new User cards one by one, now 

to swipe the Master card again, so new User cards have been made. only 2720pcs user cards can 

be made in the system.

4) 

:

Open the door by ID user card

    

Under standby, to swipe the active access ID user card on the access window will open the door, 

if the User card is not activated by the Master card, then the door can not be open and Dee beep 

will be heard at 3 times.

10.User Instructions of RFID Access Control

Содержание FP-619

Страница 1: ...100 010 110 001 101 011 111 000 First door station 100 Second door station 010 Third door station 110 Fourth door station If there s extra camera connected with the system The door station ID would b...

Страница 2: ...Separator MUST be installed side by side with Power supply 4 Monitor each one with an unique User Code note that all the bit 6 of the DIP should be set to 1 ON in this case 5 Video distributor set sw...

Страница 3: ...COM GND GND OPEN CN3 Exit button Revision PL161226 Power ON to open Power on to unlock type 1 The door lock power for a 12v DC strike max current 250mA 2 Set the jumper SIP1 set to 1 2 for a normally...

Страница 4: ...2 3 4 5 Code 2 4 ON DIP 6 7 1 2 3 4 5 Code 4 4 ON DIP 6 7 1 2 3 4 5 Code 1 4 ON DIP 6 7 1 2 3 4 5 Code 3 4 ON DIP 6 7 1 2 3 4 5 Code 10 4 ON DIP 6 7 1 2 3 4 5 Code 12 4 ON DIP 6 7 1 2 3 4 5 Code 9 4...

Страница 5: ...N ON DIP DIP DIP 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 ON ON ON DIP DIP DIP 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 ON ON ON DIP DIP DIP 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 ON ON ON DIP DIP DIP 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5...

Страница 6: ...n camera and extra camera see bellow Inner Call User can call other apartments by pressing ALARM button To start the Inner call first you need to setup a dial number on the monitor How to setup the di...

Страница 7: ...de 12 Code 9 Code 11 85 260AC ON ON ON DIP DIP DIP 6 6 6 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 ID 00 Multi monitors wiring Power supply Working Temperature Wiring Dimension DC20 30V 10 C 40 C 2 wires Non pola...

Страница 8: ...l be turn off Detection period Self detection will be happened regularly according rules and in use indicator will flash rapidly three times when check happens 1st detection will be happened in 10 sec...

Страница 9: ...al carefully before using the product 2 wire Accessories Power supply USER MANUAL Revision PL161226 Please read this manual carefully before using the product 2 wire Accessories Power supply USER MANU...

Страница 10: ...2 M 3 18 9 38 117 22 150 6 5 9 119 196 61 180 L AC N AC V V VADJ LED V V DIN rail mounting Unit mm Box mounting 100 120VAC 2 5A 200 240VAC 1 5A 50 60 Hz 24Vdc 1 5A 20 C 60 C o Input Voltage Input Fre...

Страница 11: ...read this manual carefully before using the product Please read this manual carefully before using the product 2 wire Accessories 2 wire Accessories Power Separator Power Separator USER MANUAL USER M...

Страница 12: ...C 2 wires Non polarity 89 H 70 W 45 D mm o Power supply Working Temperature Wiring Dimension o 1 2 Direct wall mounted DIN Rail mounted Connect to monitors Connect to door station 2 Parts and Functio...

Страница 13: ...3 DIP 6 OFF Code 4 DIP 6 ON Code 1 DIP 6 OFF Code 1 DIP 6 OFF Code 1 DIP 6 ON Code 0 Code 1 Code 2 Code 3 Multi door station Multi monitor in same code Multi monitor in different code 3 monitors in sa...

Отзывы: