13
GAIA 160HY-Hybrid Pixhawk 2.1
User Manual
Voltage may drop 2~3 V when encounters air turbulence or Hard maneuver. If the voltage drops
rapidly below 45 V, great attention should be given, and the drone should be landed and inspected
when necessary.
Landing
Follow the steps below to use Landing:
1.push the throttle stick down, Release stick once the motors have stopped.
2.Switch the three-position switch to "idle", cooled down NOVA generator for about 30 seconds.
3.Switch the three-position switch to "stop". NOVA will stop.
4.Plug off.
Fuel depletion may damage NOVA. Monitor fuel level with given sensor and land before fuel ran
out. To monitor fuel level, please purchase Liquid level display.
!