Calibration Procedures
Choose an open space to carry out the following procedures.
1.Hold and rotate the aircraft horizontally 360 degrees, as shown below:
Note: During the rotation, try to keep the drone as stable as possible.
2.Hold the aircraft vertically with nose pointing downward, and rotate it 360 degrees around the center axis,
as shown below:
Flow Calibration
When spraying for the first time, be sure to perform flow calibration, otherwise it will seriously affect the
operation. Always use the measuring cup in the package for water injection to ensure accuracy. The entire
calibration process takes approximately 6 - 14 minutes, please be patient.
1. Preparation before calibration: Exclude pipe air (if it is excluded, flow calibration can be performed
directly)
((1) Add approximately 2 L of water to the work box.
((2) 2 Turn on the remote control and connect the aircraft to the power source.
((3) Open the four pressure relief valves, short press the remote control spray button to turn on the spray
until the air in the pipe is exhausted*, then close the pressure relief valve and stop spraying.
* If the air cannot be removed for a long time, completely unscrew the pressure relief valve cover to remove
it, and drain the air before replacing the cover.
2. Flow calibration
((1)(level gauge calibration
Add approximately 1 L of water to the pesticide tank. Go to the App's job interface, click > , and click
the “Calibrate” button on the right side of the flow.