11
STEP-5
Repeat STEP-3 through STEP-4 to insert more batteries (up to 12 batteries).
6.5 System Start up
·
When connected with inverter, the inverter should be turned on first to avoid the current pulse of the
inverter increasing to the battery pack.
·
All installation and operation must comply with local electrical standards.
·
Check all power cables and communication cables carefully.
1.
Turn on the POWER switch
Dial address selection
Definition of dial switch for parallel machine: When the battery pack is connected with multiple machines
in parallel, the dial switch can be used to distinguish different pack addresses. The hardware address can
be set by the dial switch on the board. Addresses 1, 2, 3, and 4 represent the online number of batteries
(only the host needs to be configured), 5, 6, 7, and 8 represent the slave address. The slave address
needs to be continuous, and can support up to 12 batteries in parallel.
Single machine address setting: 0001 0000
Parallel machine address setting: refer to the table below for the definition of dial switch.
For example, three machines are in parallel, and the dial switch example is as follows:
Master dial: 0011 0000, slave 1 dial: 0000 0001, slave 2 dial: 0000 0010
Slave address
Address
Dial switch position
Description
ADDR8
ADDR7
ADDR6
ADDR5
3
ON
OFF
OFF
OFF
PACK 1
4
OFF
ON
OFF
OFF
PACK 2
5
ON
ON
OFF
OFF
PACK 3
6
OFF
OFF
ON
OFF
PACK 4
7
ON
OFF
ON
OFF
PACK 5
8
OFF
ON
ON
OFF
PACK 6
9
ON
ON
ON
OFF
PACK 7
10
OFF
OFF
OFF
ON
PACK 8
11
ON
OFF
OFF
ON
PACK 9
12
OFF
ON
OFF
ON
PACK 10
13
ON
ON
OFF
ON
PACK 11