background image

5

88

6. Use Up or Down arrow key to select the desired strip size when entering “

Strip 

Size

” menu. The default value is 64K. Press <Enter>.

7. In “

Capacity

” item, use the default value, and press <Enter>. The default value is  

twice that of the smallest hard disk size, that is, 74.5GB * 2 = 149GB.

8. Select “

Create Volume

” and press <Enter>. A warning message will appear : 

  Press <Y> to create the volume and return to the main menu.

    

WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.

    Are you sure you want to create this volume ? (Y/N) :

          

Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5

                    Copyright(C) 2003-04 Intel Corporation All Rights Reserved.

   

  

   

  

 

 

 

 

The following are typical values:

   

  

 

 

RAID0   -  128KB

   

  

 

 

RAID10 -  64KB

   

  

 

 

RAID5   -  64KB

 

Intel(R) Rapid Storage Technology - Option ROM - 9.5.0.1021                 

Copyright(C) 2003-09 Intel Corporation.   All Rights Reserved.

Name:  

RAID Level:

Disks:

Strip Size:

Capacity:

Sync:

  TryRAID5
  RAID5(Parity)
  Select Disks
   128K

   149.1   GB

   

N/A

  Create Volume

               [↑↓]-Change      [TAB]-Next      [ESC]-Previous Menu      [ENTER]-Select

[

 

HELP

 

]

64KB

CREATE VOLUME MENU 

]

          

Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5

                    Copyright(C) 2003-04 Intel Corporation All Rights Reserved.

   

 1. Create RAID Volume  

 

4. Recover Volume Options

   

2. Delete RAID Volume 

 

5. Acceleration Options

   

3. Reset Disks to Non-RAID   

6. Exit

 
   

  

 

 

 

 

  RAID Volume : 

 

 

 

  ID 

Name 

 

Level                 Stripe 

Size  Status            Bootable

  0 

TryRAID5 

 

RAID5(Parity)     64KB  149.1GB 

Normal

                Yes

  Physical Disks:
  Port  Drive Model   

Serial # 

Size 

Type/Status(Vol ID)

  0 

Hitachi HDS72161 

PVF904Z21G2JZM 

149.0GB 

Member Disk(0)

  1 

ST380811AS   

5PS1TAGW 

74.5GB 

Member Disk(0)

  2 

SAMSUNG HD161HJ

  S0V3J9APA30524 

149.0GB 

Member Disk(0)

  3 

ST380815AS   

5RW1CA37

 

74.5GB 

Non-RAID Disk

 

Intel(R) Rapid Storage Technology - Option ROM - 9.5.0.1021                 

Copyright(C) 2003-09 Intel Corporation.   All Rights Reserved.

[

 

DISK/VOLUME INFORMATION

 

]

[

 

MAIN MENU

 

]

1. Create RAID Volume

                  [↑↓]-Select                        [ESC]-Exit                       [ENTER]-Select Menu

Содержание P55MX Series

Страница 1: ...P55MX Series Motherboard User s Manual ...

Страница 2: ...indicates that this product may not be treated as household waste By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could other wise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your househo...

Страница 3: ...adio disturbance characteristics of information technology equipment EN 61000 3 2 2000 Electromagnetic compatibility EMC Part 3 Limits Section 2 Limits for harmonic current emissions equipment input current 16A per phase EN 61000 3 3 A1 2001 Electromagnetic compatibility EMC Part 3 Limits Section 2 Limits of voltage fluctuations and flicker in low voltage supply systems for equipment with rated cu...

Страница 4: ...turer HON HAI PRECISION INDUSTRY COMPANY LTD Address 66 CHUNG SHAN RD TU CHENG INDUSTRIAL DISTRICT TAIPEI HSIEN TAIWAN R O C Supplementary Information This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Страница 5: ... power please make sure the power supply AC input voltage setting has been configured to the local standard To prevent damage to the motherboard do not allow screws to come in contact with the motherboard circuit or its components Also make sure there are no leftover screws or metal components placed on the motherboard or within the computer casing If you are uncertain about any installation steps...

Страница 6: ...Main Menu 20 System Information 22 Advanced BIOS Features 24 Fox Central Control Unit 27 Advanced Chipset Features 30 Integrated Peripherals 31 Power Management Setup 35 PC Health Status 37 BIOS Security Features 38 Load Optimal Defaults 39 Save Changes and Exit 39 Discard Changes and Exit 39 Chapter 4 CD Instruction Utility CD content 41 Install driver and utility 42 FOX ONE Main Page 44 CPU Cont...

Страница 7: ... 70 BIOS Configuration 72 Create RAID in BIOS 72 Install a New Windows XP 101 Technical Support Website http www foxconnchannel com Support Website http www foxconnsupport com Worldwide online contact Support http www foxconnsupport com inquiry aspx CPU Support List http www foxconnsupport com cpusupportlist aspx Memory VGA Compatibility List http www foxconnsupport com complist aspx Support ...

Страница 8: ...nly what you need for break through performance With advanced overclocking capability and a range of connectivity features for today multi media computing requirements P55MX enables you to unleash more power from your computer This chapter includes the following information Product Specifications Layout Back Panel Connectors ...

Страница 9: ...ctors 300MB s data transfer rate Support hot plug and NCQ Native Command Queuing USB Support hot plug Supports up to 14 x USB 2 0 ports 6 rear panel ports 4 onboard USB head ers supporting 8 extra ports Support USB 2 0 protocol up to 480Mb s Internal Connectors 1 x 24 pin ATX main power connector 1 x 4 pin ATX 12V power connector 1 x CPU fan header 4 pin 2 x System fan headers 4 pin 1 x Floppy Dis...

Страница 10: ...atures PCI Express x16 Gen2 0 Support 8GB s 16GB s concurrent bandwidth Low power consumption and power management features Green Function Support ACPI Advanced Configuration and Power Interface Support S0 normal S1 power on suspend S3 suspend to RAM S4 suspend to disk and S5 soft off Bundled Software FOX ONE FOX LiveUpdate FOX LOGO FOX DMI Operating System Support for Microsoft Windows Vista XP F...

Страница 11: ...6 Front Audio Connector 7 S PDIF Out Connector 8 Speaker Connector 9 MFG Jumper 10 Front USB Connectors 11 Clear CMOS Jumper 12 Front Panel Connector 13 Chipset Intel P55 14 SATA Connectors 15 SYS_FAN2 Header 16 24 pin ATX Power Connector 17 Floppy Connector 18 IrDA Connector 19 TPM Connector 20 DDR3 DIMM Slots 21 COM2 Connector 22 CPU_FAN Header 23 LGA1156 CPU Socket 1 15 7 18 21 20 3 6 2 4 16 5 ...

Страница 12: ...each audio port please refer to the table below LAN Type Left Active Right Link Status Description Status Description 1000M Off No Link Off No Link Green Blinking Data Activity Off 10Mb s Connection Green 100Mb s Connection Orange 1000Mb s Connection Active LED Link LED Optical S PDIF Out Port LAN Port PS 2 Port Audio Ports Line Out Microphone In Subwoofer Rear Speaker Side Speaker Line In 3 1 Ser...

Страница 13: ...ut prior to any installation and read the contents in this chapter carefully This chapter includes the following information Install the CPU and CPU Cooler Install the Memory Install an Expansion Card Install other Internal Connectors Jumpers Please visit the following website for more supporting information about your motherboard CPU Support List http www foxconnsupport com cpusupportlist aspx Me...

Страница 14: ...rwise overheating and damage of the CPU may occur Set the CPU host frequency in accordance with the CPU specifications It is not recommended that the system bus frequency be set beyond hardware specifications since it does not meet the standard requirements for the peripherals If you wish to set the frequency beyond the standard specifications please do so according to your hardware specifications...

Страница 15: ...the CPU socket lever back to its locked position 4 Check pin one marking triangle with the pin one corner of the CPU socket align the CPU notches with the socket alignment keys and gently put the CPU onto the socket Before installing the CPU make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the CPU C A U T I O N 1 Release the CPU socket lever ...

Страница 16: ...e solder side of the motherboard the push pin should be fixed as depicted in the picture 3 2 1 4 Attach the 4 wire CPU cooler connector to the CPU FAN header on the motherboard Release bolts of CPU cooler from motherboard 1 Turning the push pin bolt along with the direction of arrow counterclockwise 2 Pull the push pin straight up 3 Turning push pin clockwise to its default position Use extreme ca...

Страница 17: ...e memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert the memory switch the direction C A U T I O N It is rec...

Страница 18: ...emory socket Place the memory module onto the socket then put your fingers on top edge of the module and push it down firmly and seat it vertically into the memory socket Step 2 The clips at both ends of the socket will snap into place when the memory module is securely inserted Notch Before installing a memory module make sure to turn off the computer and unplug the power cord from the power outl...

Страница 19: ...ny required BIOS changes for your expansion card s 7 Install the driver provided with the expansion card in your operating system Installing and Removing a PCI Express x16 Graphics Card Installing a Graphics Card Gently insert the graphics card into the PCI Express x16 slot Make sure the graphics card is locked by the latch at the end of the PCI Express x16 slot Removing the Card Push the latch at...

Страница 20: ...to the connector and make sure it is secure 4 pin ATX 12 V Power Connector PWR2 Connect the 8 pin ATX 12V power supply to PWR2 and provides power to the CPU Pin Definition Pin Definition 1 3 3V 13 3 3V 2 3 3V 14 12V 3 GND 15 GND 4 5V 16 PS_ON Soft On Off 5 GND 17 GND 6 5V 18 GND 7 GND 19 GND 8 Power Good 20 NC 9 5V SB Stand by 5V 21 5V 10 12V 22 5V 11 12V 23 5V 12 3 3V 24 GND We recommend you usin...

Страница 21: ... connector is used to connect with SATA Hard Disk or CD devices which support this feature The current Serial ATA II interface allows up to 300MB s data transfer rate Floppy Disk Drive Connectors FLOPPY This motherboard includes a standard floppy disk drive FDD connector supporting 360KB 720KB 1 2MB 1 44MB and 2 88MB FDDs IrDA Connector IR This connector supports infrared wireless trans mitting an...

Страница 22: ... directional with sign Power Switch Connector PWR SW Connect to the power button on the front panel of the chassis Push this switch allows the system to be turned on and off rather than using the power supply button TPM Connector TPM The TPM Trusted Platform Module provides the ability to the PC to run applications more secure and to make transactions and communication more trustworthy To utilize ...

Страница 23: ...FAN1 2 There are three main fan headers on this motherboard The fan speed can be controlled and monitored in PC Health Status section of the BIOS Setup These fans can be automatically turned off after the system enters 3 S4 and S5 sleeping states NC SPKJ EMPTY SPEAKER SPKJ 1 2 3 4 CPU_FAN SYS_FAN1 2 GND POWER SENSE CONTROL 1 ...

Страница 24: ...rdous ESD Electrical Static Discharge problem Clear CMOS Jumper CLR_CMOS The motherboard uses CMOS RAM to store the basic hardware information such as BIOS data date time information hardware password etc Clear CMOS data is the fast way to go back to factory default when the BIOS settings were mistakenly modified The steps to clear CMOS data are 1 Turn off the computer unplug the power cord from t...

Страница 25: ...t It provides latest IT management features such as Intel AMT that allows to improve management of corporate assets Set the jumper to pins 1 2 you can enable the Intel Management Engine function Set the jumper to pins 2 3 you can disable the Intel Management Engine function Enable Default 1 2 3 Disable 1 2 3 MFG Before flashing BIOS ROM you need to set MFG jumper to pins 2 3 first C A U T I O N ...

Страница 26: ...information Enter BIOS Setup Main Menu System Information Advanced BIOS Features Fox Central Control Unit Advanced Chipset Features Integrated Peripherals Power Management Setup PC Health Status BIOS Security Features Load Optimal Defaults Save Exit Setup Exit Without Saving Since BIOS could be updated some other times the BIOS information described in this manual is for reference only We do not g...

Страница 27: ...tral Control Unit Some special proprietary features such as overclocking can be set up through this menu Advanced Chipset Features The values for the chipset can be changed through this menu and the system performance can be optimized Integrated Peripherals All onboard peripherals can be set up through this menu There are IDE devices Super I O devices such as Serial I O and other USB devices etc W...

Страница 28: ...word before boot or access to Setup Load Optimal Defaults The optimal performance settings can be loaded through this menu However it may offer bet ter performance in some ways such as less I O cards less memory etc still it may cause problem if you have more memory or I O cards installed It means if your system loading is heavy set to optimal default may sometimes come out an unstable system What...

Страница 29: ...ich kind of the Floppy Disk Drive is installed in your system It can be Disabled 360KB 51 4 1 2MB 51 4 720KB 31 2 1 44MB 31 2 and 2 88 MB 31 2 Halt On This category determines whether or not the computer will stop if an error is detected during powering up All Errors All errors can result in system halt All Errors But All errors but keyboard or mouse can result in system halt The halt condi tion c...

Страница 30: ...f you enabled this item Model Name Model name of this product BIOS Version It displays the current BIOS version User can check this information and discuss with the field service people if a BIOS upgrade is needed Memory This item displays the current memory size The size is depending on how many memory mod ules were installed in your system before powering on MAC Address This item shows the onboa...

Страница 31: ...system is started The available settings are On default and Off PCI Latency Timer This item is used to set the value in units of PCI clocks for PCI device latency timer register Floppy Drive Seek This item controls whether the BIOS will be checking for a floppy drive while booting up If it cannot detect one either due to improper configuration or physical unavailability it will ap pear an error me...

Страница 32: ...t C 1985 2009 American Megatrends Inc Trusted Computing Trusted Computing Help Item TCG TPM Support Enable Disable TPM TCG TPM 1 1 1 2 support in BIOS Move Enter Select Value F10 Save ESC Exit F1 General Help F9 Optimized Defaults No TCG TPM Support Trusted Computing Group TCG members develop and promote open vendor neutral industry standard specifications for trusted computing building blocks and...

Страница 33: ...rk group members should have a working knowl edge of security in relation to the design and usage of cryptographic modules Members should also have a working knowledge of cryptographic techniques including public key cryp tography cryptographic algorithms and protocols This item is used to enable disable the function of TCG TPM support ...

Страница 34: ...ect SPD device is a small EEPROM chip mounted on a memory module It contains important information about the module s speed size addressing mode and various other parameters so that the motherboard memory controller chipset can better access the memory device Select Auto for SPD enable mode Select Manual to set the parameters by yourself The following 10 settings are valid only when the Memory Tim...

Страница 35: ...Module Version 01 06 Manufacturer Intel Genuine Intel R CPU 000 2 67GHz Frequency 2 66GHz BCLK Speed 133MHz Cache L1 256KB Cache L2 1024KB Cache L3 8192KB C1E Support Enabled MPS and ACPI MADT ordering Modern ordering Limit CPUID MaxVal Disabled Virtualization Technology Enabled Execute Disable Bit Enabled Intel R HT Technology Enabled Active Processor Cores All A20M Disabled EIST Function Disable...

Страница 36: ...d systems can halt worm attacks reducing the need for virus related repairs By combining Execute Disable Bit with anti virus firewall spyware removal e mail filtering software and other network security measures IT managers can free IT resources for other initiatives Intel R HT Technology This item is used to enable disable the Hyper Threading Technology feature Active Processor Cores This item is...

Страница 37: ...ure out what to do Many systems cause that high RAM to simply be ignored resulting in the loss of effective RAM More complex systems will take the RAM that would occupy that 3 5 4GB address space and re map it into the 4 0 4 5GB address space The RAM doesn t care because it s just an array of storage cells it s up to the memory controller to associate addresses with those storage cells Of course t...

Страница 38: ...Megatrends Inc IDE Configuration Configure SATA as IDE Help Item SATA 1 IDE Configuration Enhanced SATA 2 IDE Configuration Enhanced IDE Detect Time Out 35 IDE RAID AHCI Disabled Move Enter Select Value F10 Save ESC Exit F1 General Help F9 Optimized Defaults IDE Options Configure SATA as This item is used to set the operation mode of your SATA ports 1 2 3 4 5 6 Set to IDE can configure the SATA po...

Страница 39: ... LAN Controller This item is used to enable or disable the onboard LAN controller OnBoard LAN Boot ROM This item is used to enable or disable the onboard LAN boot optional ROM A LAN boot ROM lets you set up a diskless workstation on the network By installing a boot ROM in the network board you can enable a client PC system on the network to be booted remotely SuperIO Configuration CMOS Setup Utili...

Страница 40: ...09 American Megatrends Inc USB Configuration USB Configuration Help Item Module Version 2 24 5 13 4 USB Devices Enabled 2 Hubs Legacy USB Support USB 2 0 Controller Mode HiSpeed BIOS EHCI Hand Off Enabled USB Storage Configuration Press Enter Move Enter Select Value F10 Save ESC Exit F1 General Help F9 Optimized Defaults Enabled Enables support for legacy USB AUTO option disables legacy support if...

Страница 41: ...e following item will appear USB Storage Configuration After pressing Enter you can set the reset delay for the USB mass storage device There are many different emulation types of this USB device such as Auto Floppy Forced FDD Hard Disk and CDROM can be selected Select Auto USB devices less than 530MB will be emulated as Floppy and remaining as hard drive Forced FDD option can be used to force a H...

Страница 42: ...tate except that the CPU and system cache context is lost the OS is respon sible for maintaining the caches and CPU context Control starts from the processor s reset vector after the wake event S3 The S3 sleeping state is a low wake latency sleeping state where all system context is lost except system memory CPU cache and chip set context are lost in this state Hardware maintains memory context an...

Страница 43: ...suitable now USB Device Wakeup From S3 This item is used to wake up the system by a USB device when it is staying at S3 state Power On after Power Fail This item is used to set which state the PC will take with when it resumes after an AC power loss Resume by PCIE PME This item is used to enable disable the PCI Express device to generate a wake up Resume by PCI Card This item is used to enable dis...

Страница 44: ...e temperature exceeds the set value the system will shut down automatically This function works only when your operating system is supporting ACPI CPU System Temperature The CPU System temperature are automatically detected and displayed by the system CPU System Fan1 Speed System Fan2 Speed The CPU System fan speed are automatically detected and displayed by the system CPU Core DRAM Voltage 3 30V ...

Страница 45: ...password it then will ask you to input user password optionally User Access Level This item is used to set user access level The available settings are No Access Prevent user access to the setup utility View Only Allow access to the setup utility but the fields can not be changed Limited Allow only limited fields to be changed such as date and time Full Access Allow any field to be changed except ...

Страница 46: ...ers to be set cannot be supported by your hardware devices for example too many expansion cards were installed the system might fail to work Save Exit Setup When you select this option and press Enter a message will be displayed in the center of the screen Select OK to save your changes to CMOS and exit the pro gram select Cancel or ESC to return to the main menu Exit Without Saving If you select ...

Страница 47: ...s that enhance the motherboard features This chapter includes the following information Utility CD content Install driver and utility FOX ONE FOX LiveUpdate FOX LOGO FOX DMI Note Because each module is independent so the section number will be reorganized and unique to each module please understand ...

Страница 48: ... D Intel RAID Driver 1 2 Software Utilities Use these options to install additional software programs FOX ONE is a very powerful user inter face program which allows you to change your system setting without going to BIOS Some auto features help user to improve or overclock your system without being a computer literate A FOX ONE B FOX LiveUpdate C FOX LOGO D FOX DMI E Microsoft DirectX 9 0 2 F Ado...

Страница 49: ...all the other drivers left or you can click on each individual driver to install it manually 2 Install Utility You can select the specific utility to install Manual Instal lation Step by Step Automatic Installation by One Click Select to Install Utilities Select to Install Drivers Click to visit Foxconn s website Browse CD Exit the program Drop to System Tray ...

Страница 50: ...ill require you to calibrate the CPU s loading Click OK to proceed and start the Utility F I S is a feature of FOX ONE which can automatically adjust your CPU clock based on your current system loading Before you running the FOX ONE program the system parameters such as CPU clock voltage etc are controlled by BIOS settings After you run FOX ONE it will take over and the controlling right will be t...

Страница 51: ...implify the whole FOX ONE control panel to a smaller information bar i e Simple Mode as depicted below you can drag this bar to any place on your screen to help you monitoring system status Click here to go back to FOX ONE full screen Click here will drop the FOX ONE to Windows system tray Exit FOX ONE Show CPU Information Toolbar Alert Lamp Switch Button Exit Minimum Homepage Monitor Frequency Vo...

Страница 52: ...it Click this button to exit the program Minimum Click this button to drop the FOX ONE to Windows system tray located at the lower right corner of your screen Homepage Click this button to visit Foxconn motherboard website http www foxconnchannel com Apply the changes Click the new skin picture to select the new skin Cancel the changes ...

Страница 53: ...the Simple Mode Messages such as CPU frequency voltage etc they can be displayed one by one in Simple Mode 3 F I S Calibration FOX Intelligent Stepping Optional This function will re calibrate the CPU s loading and it may take several minutes to proceed The FOX ONE calibration process will apply different loadings to your CPU record PWM IC voltage together with the CPU clock running at these loadi...

Страница 54: ... 2 After data is collected it will ask you to restart your computer now Later on when the FOX ONE program is activated and F I S feature in CPU Page is also enabled FOX ONE will automatically adjust your CPU clock according to your system loadings Loadings are like Power Gaming Data Mining etc ...

Страница 55: ...heck the highest CPU clock you can use System will raise the CPU clock step by step until it hangs you can then push the RESET button on your PC panel to restart the system When system restarts run FOX ONE again it will display a recommended highest CPU clock for you click Yes to apply it A message informs you to push RESET button later if the system hangs finally Click Yes to continue Press Auto ...

Страница 56: ...SET button on the front panel of your system to restart the computer Run FOX ONE program again it will inform you the previous test found that 255MHz is the recommended CPU clock for your system Click Yes to apply it to your system Now your system is running at a CPU clock of 255MHz ...

Страница 57: ...ts speed to a minimum The four benchmarks Power Gaming Data Mining Office and Energy Saving the references of their system loading were calculated and defined in the FIS Calibration option of Configuration menu Select Auto CPU will automatically adjust its clock according to current system loading 3 Frequency Page Frequency Control This page lets you set memory and PCI Express frequencies by manua...

Страница 58: ...lert function Go to Limit Setting page Set high limit by dragging the lever Show current CPU temperature value Enable alert function when the CPU temperature is higher than high limit value Show current high limit value of the CPU temperature Set high limit by dragging the lever Show current system temperature value Enable alert function when the system temperature is higher than high limit value ...

Страница 59: ...alert function Set low limit rpm by dragging the lever Show current CPU fan rpm value Enable alert function when the CPU fan runs slower than the low limit rpm value Show current low limit rpm value of CPU fan Set low limit rpm by dragging the lever Show current system fan rpm value Enable alert function when the system fan runs slower than low limit rpm value Show current low limit rpm value of s...

Страница 60: ...tage manually CPU voltage can be stepped up down by a unit of 12 5mV while memory is 0 05V step and North Bridge is 0 04V step Set low limit rpm by dragging the lever Show current FAN1 fan rpm value Enable alert function when the FAN1 fan runs slower than low limit rpm value Show current low limit rpm value of FAN1 fan Go to Voltage page Select the option you want to set Adjust by manual Reset the...

Страница 61: ...ets you enable Smart Fan function or set the fan speed by manual When Smart Fan is selected you must use a 4 pin CPU cooler in your system Go to Fan page Set fan speed by dragging the lever Enable or disable smart fan function Apply the changes ...

Страница 62: ...03 32 bit and 64 bit Windows Vista 32 bit and 64 bit Using FOX LiveUpdate 1 Local Update 1 1 Local Update BIOS Information This page lets you know your system BIOS information please refer to the physical motherboard for detail Exit Toolbar Minimum Show current BIOS information Link to website Please set the BIOS setting BIOS Write Protect or Super BIOS Protect to Disabled when running this applic...

Страница 63: ...ensure if you really want to continue click Yes to confirm A setup wizard will guide you to load a local BIOS file to finish the operation You must remember from which directory to load your new BIOS file with an extension of BIN for Award BIOS ROM for AMI BIOS before the setup wizard starts Key in a BIOS name Click here FOX LiveUpdate can automatically backup old BIOS before update This feature c...

Страница 64: ...ration 2 2 Online Update Update Driver This page lets you update your system drivers from Internet Click start it will search the new drivers from Internet Then follow the wizard to finish the update operation Click here Current information Search new BIOS from Internet Browse detailed information Update BIOS Close the window Select BIOS to update Click here Current information Search new drivers ...

Страница 65: ...from Internet Then follow the wizard to finish the update operation Browse detailed information Install the selected driver Close the window Select the driver to update Click here Current information Search new utilities from Internet Browse detailed information Install the selected utility Close the window Select the utility to update ...

Страница 66: ...will search all new BIOS drivers utilities from Internet Then follow the wizard to finish the update operation Click here Current information Search all new BIOS drivers utilities from Internet Browse detailed BIOS information Close the window Browse detailed driver information Browse detailed utility information ...

Страница 67: ...rom Internet and if any qualified item found it will pop out a message on the task bar to inform you to do the next step Double click on the icon as show below you can see the detailed information Double click here Apply the changes Reset to default value Click here Set auto search options Select search which kind of versions Set auto search the latest FOX LiveUpdate ...

Страница 68: ...igure System This page lets you set the backup BIOS location and change different skin of the FOX LiveUpdate utility Click here Set the location of download files or auto backup BIOS Determine if the FOX LiveUpdate can auto run when the system starts up Select different skin of the software Apply the changes Reset to default value Prompt you to install the new FOX LiveUpdate ...

Страница 69: ...thout any interruption 4 About Help This page shows some information about FOX LiveUpdate C A U T I O N We recommend that you had better keep the default setting unchanged to avoid any damage Click here Select which BIOS ROM to flash Only available to motherboard with backup BIOS ROM Apply the changes Reset to default value Select to flash Boot Block Select to clear CMOS Click here Show informatio...

Страница 70: ...layed if you enable the BIOS Quiet Boot setting in Advanced BIOS Features menu Supporting Operating Systems Windows 2000 Windows XP 32 bit and 64 bit Windows 2003 32 bit and 64 bit Windows Vista 32 bit and 64 bit Using FOX LOGO Main Page When you change Logo or delete current Logo the system will flash BIOS file auto matically During this time please DO NOT shut down the application and the system...

Страница 71: ...an easily analyze and troubleshoot your mother board if there is any problem occurred Supporting Operating Systems Windows 2000 Windows XP 32 bit and 64 bit Windows 2003 32 bit and 64 bit Windows Vista 32 bit and 64 bit Using FOX DMI Please operate this utility as the comments shows Click here to select the DMI Data format you need Click here to select the type you want to view ...

Страница 72: ...is chapter will include the following information RAID Configuration Introduction Intel Matrix Storage Manager Create a RAID Driver Diskette BIOS Configuration Create RAID in BIOS Install a New Windows XP ...

Страница 73: ...d can skip this step 2 Follow 5 2 to set BIOS setting SATA Mode to RAID or AHCI 3 Follow 5 3 to create RAID in BIOS 4 Follow 5 4 to Install Windows Operating System What kinds of hardware and software you need here 1 A floppy drive 2 A CD ROM drive 3 Several SATA hard disks 4 A RAID driver diskette 5 A motherboard driver CD 6 Windows XP or Vista Install CD ...

Страница 74: ...r where speed is important for example a system that delivers video on demand TV programs to many viewers The configuration affects reliability and performance in different ways The problem with using more disks is that it is more likely that one will go wrong but by using error checking the total system can be made more reliable by being able to survive and repair the failure Basic mirroring can ...

Страница 75: ... fails data access will not be affected as long as there are other working drives in the array RAID 5 Parity RAID 5 provides data striping at the byte level and also stripes error correction information This results in excellent performance and good fault tolerance Level 5 is one of the most popular implementations of RAID RAID 10 0 1 RAID 10 is a combination of striping and mirroring This configu...

Страница 76: ...ion easier The topic will be introduced Installing a new Windows XP in a brand new RAID system Steps to Install Serial ATA Hard Disks 1 Install SATA hard disks into the drive bays 2 Connect one end of the SATA cable to motherboard s SATA connector and the other end to SATA hard disk 3 Connect SATA power cable to the power connector of SATA hard disk Before installing the SATA hard disks make sure ...

Страница 77: ...ation 3 Click GO to start 4 Select the desired destination FDD drive It can be the default drive A or any USB FDD Click OK to continue 5 Insert a diskette click OK to continue 5 1 Create a RAID driver diskette If you want to install a brand new Windows XP on a AHCI or RAID system you need to configure the SATA Mode in BIOS to either AHCI or RAID first You also need to create a RAID driver diskette...

Страница 78: ...tional specific devices for example a RAID device 10 Install Serial ATA Hard Disks 10 1 Shut down your computer 10 2 Install SATA hard disks into the drive bays connect all power and SATA cables 6 You can input a volume label for this diskette click on Start to format 7 Click on OK to go through this warning message 8 Format finished Click OK to continue copying of RAID driver into this diskette ...

Страница 79: ...n Configure SATA as RAID Help Item IDE Detect Time Out 35 IDE RAID AHCI Disabled Move Enter Select Value F10 Save ESC Exit F1 General Help F9 Optimized Defaults RAID Options Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acceleration Options 3 Reset Dis...

Страница 80: ...ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved HELP Name RAID Level Disks Strip Size Capacity Sync TryRAID0 RAID0 Stripe Select Disks 128KB 0 0 GB N A Create Volume RAID0 Stripe Change TAB Next ESC Previous Menu ENTER Select CREATE VOLUME MENU Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved Enter...

Страница 81: ... the volume Prev Next SPACE SelectDisk ENTER Done 2 SAMSUNG HD161HJ S0V3J9APA30524 149 0GB Non RAID Disk Intel R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved Change TAB Next ESC Previous Menu ENTER Select CREATE VOLUME MENU SELECT DISKS Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporatio...

Страница 82: ...H9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved The default value indicates the maximum capacity using the selected disks Entering a lower capacity allows you to create a second volume on these disks Intel R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved Name RAID Level Disks Strip Size Capacity TryRAID0 RAID0 Stripe Se...

Страница 83: ... 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved HELP Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acceleration Options 3 Reset Disks to Non RAID 6 Exit RAID Volume ID Name Level Stripe Size Status Bootable 0 TryRAID0 RAID0 Stripe 128KB...

Страница 84: ...ters or less Intel R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Name RAID Level Disks Strip Size Capacity Sync Volume0 RAID0 Stripe Select Disks 128KB 0 0 GB N A Create Volume Volume0 Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003...

Страница 85: ...CA37 74 5GB Non RAID Disk Select 2 to 6 disks to use in creating the volume Prev Next SPACE SelectDisk ENTER Done SELECT DISKS 0 Hitachi HDS721616PLA PVF904Z21G2JZM 149 0GB Member Disk CREATE VOLUME MENU Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved Name RAID Level TryRAID0...

Страница 86: ...ved The following are typical values RAID0 128KB RAID10 64KB RAID5 64KB Intel R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved Name RAID Level Disks Strip Size Capacity Sync TryRAID0 1 RAID0 Stripe Select Disks 128KB 148 1 GB N A Create Volume Change TAB Next ESC Previous Menu ENTER Select HELP 128KB CREATE VOLUME MENU Intel R Matrix Storag...

Страница 87: ...ID Volume ID Name Level Stripe Size Status Bootable 0 TryRAID0 RAID0 Stripe 128KB 150 0GB Normal Yes 1 TryRAID0 1 RAID0 Stripe 128KB 148 1GB Normal Yes Physical Disks Port Drive Model Serial Size Type Status Vol ID 0 Hitachi HDS72161 PVF904Z21G2JZM 149 0GB Member Disk 0 1 1 ST380811AS 5PS1TAGW 74 5GB Non RAID Disk 2 SAMSUNG HD161HJ S0V3J9APA30524 149 0GB Member Disk 0 1 3 ST380815AS 5RW1CA37 74 5G...

Страница 88: ...l R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Name RAID Level Disks Strip Size Capacity Sync Volume0 RAID0 Stripe Select Disks 128KB 0 0 GB N A Create Volume TryRAID1 Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corpor...

Страница 89: ...D161HJ S0V3J9APA30524 149 0GB Non RAID Disk 3 ST380815AS 5RW1CA37 74 5GB Non RAID Disk Select 2 disks to use in creating the volume Prev Next SPACE SelectDisk ENTER Done SELECT DISKS 0 Hitachi HDS721616PLA PVF904Z21G2JZM 149 0GB Non RAID Disk CREATE VOLUME MENU Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Inte...

Страница 90: ...ghts Reserved Name RAID Level Disks Strip Size Capacity Sync TryRAID1 RAID1 Mirror Select Disks N A 74 5 GB N A Create Volume Change TAB Next ESC Previous Menu ENTER Select HELP 74 5 CREATE VOLUME MENU Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acce...

Страница 91: ...pid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Name RAID Level Disks Strip Size Capacity Sync Volume0 RAID0 Stripe Select Disks 128KB 0 0 GB N A Create Volume TryRAID10 Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation...

Страница 92: ... 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved Name RAID Level Disks Strip Size Capacity Sync TryRAID10 RAID10 RAID0 1 Select Disks 128K 149 1 GB N A Create Volume Change TAB Next ESC Previous Menu ENTER Select HELP 64KB CREATE VOLUME MENU Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAI...

Страница 93: ...tel R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Name RAID Level Disks Strip Size Capacity Sync Volume0 RAID0 Stripe Select Disks 64KB 0 0 GB N A Create Volume TryRAID5 Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corpo...

Страница 94: ... S0V3J9APA30524 149 0GB Non RAID Disk 3 ST380815AS 5RW1CA37 74 5GB Non RAID Disk Select 3 to 6 disks to use in creating the volume Prev Next SPACE SelectDisk ENTER Done SELECT DISKS 0 Hitachi HDS721616PLA PVF904Z21G2JZM 149 0GB Non RAID Disk CREATE VOLUME MENU Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel...

Страница 95: ...d Name RAID Level Disks Strip Size Capacity Sync TryRAID5 RAID5 Parity Select Disks 128K 149 1 GB N A Create Volume Change TAB Next ESC Previous Menu ENTER Select HELP 64KB CREATE VOLUME MENU Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acceleration O...

Страница 96: ...age Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Name RAID Level Disks Strip Size Capacity Sync Volume0 RAID0 Stripe Select Disks 128KB 0 0 GB N A Create Volume TryRecovery Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All R...

Страница 97: ...S 5PS1TAGW 74 5GB Non RAID Disk 2 SAMSUNG HD161HJ S0V3J9APA30524 149 0GB Non RAID Disk 3 ST380815AS 5RW1CA37 74 5GB Non RAID Disk Select 1 Master and 1 Recovery disk to create volume Prev Next TAB M aster SPACE R ecovery ENTER Done SELECT DISKS 0 Hitachi HDS721616PLA PVF904Z21G2JZM 149 0GB Non RAID Disk CREATE VOLUME MENU Change TAB Next ESC Previous Menu ENTER Select Intel R Matrix Storage Manage...

Страница 98: ...s Port Drive Model Serial Size Type Status Vol ID 0 Hitachi HDS72161 PVF904Z21G2JZM 149 0GB Recovery Disk 0 1 ST380811AS 5PS1TAGW 74 5GB Master Disk 0 2 SAMSUNG HD161HJ S0V3J9APA30524 149 0GB Non RAID Disk 3 ST380815AS 5RW1CA37 74 5GB Non RAID Disk Intel R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved DISK VOLUME INFORMATION MAIN MENU 1 Cr...

Страница 99: ...ation All Rights Reserved HELP DELETE VOLUME MENU TryRAID5 RAID5 Parity 3 149 1GB Normal Yes Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acceleration Options 3 Reset Disks to Non RAID 6 Exit RAID Volume ID Name Level Stripe Size Status Bootable 0 Try...

Страница 100: ... ALL DATA ON SELECTED DISKS WILL BE LOST This does not apply to Recovery volumes Are you sure you want to delete TryRAID5 Y N DELETE VOLUME VERIFICATION Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acceleration Options 3 Reset Disks to Non RAID 6 Exit...

Страница 101: ...815AS 5RW1CA37 74 5GB Non RAID Disk Intel R Rapid Storage Technology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved DISK VOLUME INFORMATION MAIN MENU 3 Reset Disks to Non RAID Select ESC Exit ENTER Select Menu Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover V...

Страница 102: ...ing a disk causes all data on the disk to be lost This does not apply to Recovery volumes Port Drive Model Serial Size Status 0 Hitachi HDS721616PLA PVF904Z21G2JZM 149 0GB Member Disk 2 SAMSUNG HD161HJ S0V3J9APA30524 149 0GB Member Disk Select the disks that should be reset Previous Next SPACE Selects ENTER Selection Complete 0 Hitachi HDS721616PLA PVF904Z21G2JZM 149 0GB Member Disk RESET RAID DAT...

Страница 103: ... Selects ENTER Selection Complete Resetting RAID disk will remove its RAID structures and revert it to a non RAID disk WARNING Resetting a disk causes all data on the disk to be lost This does not apply to Recovery volumes Port Drive Model Serial Size Status 0 Hitachi HDS721616PLA PVF904Z21G2JZM 149 0GB Member Disk 1 ST380811AS 5PS1TAGW 74 5GB Member Disk 2 SAMSUNG S0V3J9APA30524 149 0GB Member Di...

Страница 104: ...C 2003 09 Intel Corporation All Rights Reserved DISK VOLUME INFORMATION MAIN MENU 3 Reset Disks to Non RAID Select ESC Exit ENTER Select Menu Intel R Matrix Storage Manager option ROM v5 0 0 1011 ICH9R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acceleration Options 3 Reset Disks to Non RAID 6 Exit RAID Volum...

Страница 105: ...echnology Option ROM 9 5 0 1021 Copyright C 2003 09 Intel Corporation All Rights Reserved 1 Enable Only Recovery Disk Select ESC Exit ENTER Select Menu HELP RECOVERY vOLUME OPTIONS Name Level Capacity Status Bootable TryRecovery Recovery Cont 74 5GB Normal Yes Select a Recovery volume to do the operation Up Down SPACE Selects ENTER Done SELECT RECOVERY VOLUME TryRecovery Recovery Cont 74 5GB Norma...

Страница 106: ...Reset Disks to Non RAID 6 Exit RAID Volume ID Name Level Stripe Size Status Bootable 0 TryRecovery Recovery OnReq N A 74 5GB NeedUpdate Yes Physical Disks Port Drive Model Serial Size Type Status Vol ID 0 Hitachi HDS72161 PVF904Z21G2JZM 149 0GB Recovery Disk 0 1 ST380811AS 5PS1TAGW 74 5GB Offline Disk 0 2 SAMSUNG HD161HJ S0V3J9APA30524 149 0GB Member Disk 0 3 ST380815AS 5RW1CA37 74 5GB Non RAID Di...

Страница 107: ...pyright C 2003 04 Intel Corporation All Rights Reserved 1 Create RAID Volume 4 Recover Volume Options 2 Delete RAID Volume 5 Acceleration Options 3 Reset Disks to Non RAID 6 Exit RAID Volume ID Name Level Stripe Size Status Bootable 0 TryRAID5 RAID5 Parity 64KB 149 1GB Normal Yes Physical Disks Port Drive Model Serial Size Type Status Vol ID 0 Hitachi HDS72161 PVF904Z21G2JZM 149 0GB Member Disk 0 ...

Страница 108: ...ly and it keeps loading files until the next screen displays Windows Setup Press F6 if you need to install a third party SCSI or RAID driver When you set the SATA Mode in BIOS to either AHCI or RAID you need to follow these steps to install your Windows XP system C A U T I O N CMOS Setup Utility Copyright C 1985 2009 American Megatrends Inc Boot Device Priority Boot Device Priority Help Item 1st B...

Страница 109: ...mine the type of one or more mass storage devices installed in your system or you have chosen to manually specify an adapter Currently Setup will load support for the following mass storage device s none To specify additional SCSI adapters CD ROM drivers or special disk controllers for use with Windows including those for which you have a device support disk from a mass storage device manufacturer...

Страница 110: ...rt disk from a mass storage device manufacturer press S If you do not have any device support disks from a mass storage device manufacturer or do not want to specify additional mass storage devices for use with Windows press ENTER S Specify Additional Device ENTER Continue F3 Exit Windows Setup You have chosen to configure a SCSI Adapter for use with Windows using a device support disk provided by...

Страница 111: ...from the floppy drive please remember 11 Follow the Windows XP install processes to finish the set up Windows XP Professional Setup The following list shows the existing partitions and unpartitioned space on this computer Use the UP ad DOWN ARROW keys to select an item in the list To set up Windows XP on the selected item press ENTER To create a partition in the unpartitioned space press C To dele...

Отзывы: