background image

 

 

 

 

       

 

 

UHF Reader User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание CMC181

Страница 1: ...UHF Reader User Manual...

Страница 2: ...nna ports can support 4 antennas in use simultaneously High reliability aluminum out case for the harsh work condition Specifications Specifications Protocol ISO18000 EPC Class1 Gen2 Operating Frequen...

Страница 3: ...nction 12V 12V power output D02 2 ways output circuit D02 D01 D01 DI 1 way input circuit DI GND Power GND Icon show 1 The fixed screw holes 2 Ant port 3 Power lamp 4 Ant lamp 5 Inventory lamp 6 Icon s...

Страница 4: ...pment storage or installed in direct sunlight high humidity dew and other heat source place 4 The cable s length between ant and UHF reader should not exceed 10 meters When the length is longer than t...

Страница 5: ...end the information to the host The system frame s sketch map is shown in figure 2 0 Figure2 0 system frame map 2 1 Presenter Name Specs Amount UHF reader 222mm 158 5mm 33 7mm 1 Reticle Standard cable...

Страница 6: ...on show Search get devices IP Open connect the device Close disconnect the device Refresh refresh the interface of the device Same line while Different antennas add count Inventory Test no add count e...

Страница 7: ...etting device s network parameters you can fill in what you want to set then click Set Config And click open to connect network if success UHF reader will show you Init OK and firmware version UHF rea...

Страница 8: ...D EPC TID USER Begin the start address is word pointer 16 bit unit Length length is word length of EPC Data data to write Read read special tag memory Write write data to special tag memory Opcode set...

Страница 9: ...nk make tag dead against ant edit data to write and click Write If it is successful you will see Write Tag OK in figure 2 8 Figure 2 8 Lock Tag Set password of tags to lock select corresponding operat...

Страница 10: ...2 11 Figure 2 11 3 Icon show Ant set the ant port Dwell Time ms set executive time of ants Power dBm set output power which arranges 0 from 30 SWR 2 check this option for ant SWR 2 do not perform the...

Страница 11: ...notes Click Log in figure 2 12 Pander Auto save to save log notes Figure 2 12 Notice This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and...

Страница 12: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may ca...

Отзывы: