background image

- 2 -

»

1-channel 230 V relay with 10 A rated capacity and 16 A ma-

ximum capacity;

»

Ability to connect local control button and set its function;

»

Monitoring of network parameters: voltage, current, power 

(active and reactive), energy (active and reactive);

»

Controlling receivers with a mobile app and time program-

mers;

»

Built-in clock with power backup and backup copy of the work 

program guarantees proper operation also without a Wi-Fi 

connection;

»

REST API support enabling integration of the controller also 

with other home automation systems;

»

Built-in thermal protection;

»

Convenient installation in an installation box with a diameter 

of �60 mm.

The ability to operate at loads above the rated value de-

pends on the temperature and operating conditions of 

the device. Prolonged operation at such high load may 

lead to tripping of the thermal protection and discon-

nection of the controlled circuits.

Properties

Содержание Wi-R1S1-P

Страница 1: ... com pl e mail biuro fif com pl Communication via home Wi Fi network Remote access to devices via the Polish F F cloud Integration with Google and Google Home voice assistant Ability to work autonomously without a Wi Fi connection Advanced programmable timers based on online calendars and enhanced with astronomical functions Free mobile applications for Android and iOS System capabilities ...

Страница 2: ...p copy of the work program guarantees proper operation also without a Wi Fi connection REST API support enabling integration of the controller also with other home automation systems Built in thermal protection Convenient installation in an installation box with a diameter of 60 mm The ability to operate at loads above the rated value de pends on the temperature and operating conditions of the dev...

Страница 3: ...le for mobile devices running the system Android version 5 0 or higher iOS version 12 or higher You can download the app directly from the stores or via the website www fif com pl fox On the above page you can also find detailed information on how to configure and operate the devices and the Fox mobile app Configuration ...

Страница 4: ...on N power supply neutral wire 3 N terminals connected inside of the device L power supply phase wire R power output for R receiver It is recommended to use monostable momentary buttons When using bistable buttons at most one pushbutton can be connected to the input Wiring diagram ...

Страница 5: ...risk that another user of the Fox application will gain access to your device If you lose access to your Fox device follow the procedure de scribed in Restore factory settings section For a detailed description of how to use the Fox appli cation see the context sensitive help for the application available under the i key in the mobile application or go to www fif com pl fox switchenergy 1 Start th...

Страница 6: ...dress used to create an account in the cloud and a password to access the cloud and add more devices In the first field Name enter the name under which the account will be displayed in the application After entering the data press the Add button Adding an account is a one time action The created ac count is visible in the list at the bottom of the screen and can be used to personalize subsequent d...

Страница 7: ...e password under which it will be visible on the device manager list such as Home administrator living room user In the Enter password field enter the content of the password Press the Add button The password is the key to access the device Devices can be grouped using the same passwords and permis sions to these groups can be delegated in the form of an assigned access password This way by decidi...

Страница 8: ... to enable the Blu etooth function on your phone and agree to access the location This will allow you to directly search for nearby Fox devices The app searches for available devices nearby that are in factory mode devices available on your local network or connected to cloud accounts for which passwords were previously entered into Password Manager The gray icon and gray device description indica...

Страница 9: ...ntrollers can only connect to Wi Fi networks ope rating in the 2 4 GHz band Set other configuration parameters as necessary user password remote access account link to the program mers calendar and the time zone and location of the device necessary for proper operation of the program mers After entering all the data press the OK button and wait for the configuration to be sent to the device The ap...

Страница 10: ... you can use the Set Defaults option at the top of the Device Configuration screen Pressing this button will substitute all recently entered data passwords Wi Fi settings remote access calendar location and time zone into the new device ...

Страница 11: ...ted on the front of the device The grey color actually corresponds to the green LED and the black color to the red LED Controller in factory mode Connecting to a Wi Fi network Connection to Wi Fi network established No connection to Wi Fi network Restoring firmware LED signalling ...

Страница 12: ...green LED will start to flash rapidly 2 After about 5 seconds the LED will turn off and you should release the PROG button 3 Press the PROG button briefly the green LED will light up aga in 4 Press and hold down the PROG button After about 3 seconds the previously switched on green control light will start to fla sh After another three seconds it will go out 5 Release the button the controller has...

Страница 13: ...ndby 1 2W operation relay on 2W communication radio frequency 2 4 GHz transmission Wi Fi radio power IEEE 802 11n 13 dBm receiver sensitivity 98 dBm terminal 2 5mm screw terminals tightening torque 0 4 Nm working temperature 0 45 C humidity 90 no condensation of steam and aggressive gases dimensions 54 size 48 43mm h 20mm mounting in ø60 flush mounted box ingress protection IP20 Technical data ...

Страница 14: ...ntial requirements of Directive 2014 53 EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repe aling Directive 1999 5 EC The CE Declaration of Conformity along with the references to the standards in relation to which conformity is declared can be found on www...

Страница 15: ......