Four Seasons Supply Old Salem Series Скачать руководство пользователя страница 1

OLD SALEM GAS COAL VENT FREE FIREPLACE 

 

Page 1 of 16

 

INSTALLATION OPERATION AND SERVICE MANUAL 

Old Salem Collection 

 

Vent Free Box with Classic Coals 

 

THIS ONLINE INSTALLATION MANUAL IS PROVIDED FOR PLANING PUPOSES ONLY. WE 

RESERVE THE RIGHT TO MAKE CHANGES TO THE PRODUCT AND THIS MANUAL FOR 

PRODUCT IMPROVEMENT PURPOSES. ALWAYS REFER TO THE INSTALLATION MANUAL 

AND INCLUDE INSTRUCTIONS PROVIDED WITH YOUR PRODUCT. 

 

 

 

 

 
 
 

 
 
 
 
 
 
 
 

PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING AND 

OPERATING 

THE 

APPLIANCE. 

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

WARNING: If the information in this manual is not followed exactly, a fire or 
explosion may result causing property damage, personal injury or loss of life. 

 

 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 

any other appliance 
 

WHAT TO DO IF YOU SMELL GAS: 

*Do not try to light any appliance. 
*Do not touch any electrical switch; do not use any phone in your building. 
*Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers 
instructions. 
*If you cannot reach your gas supplier; call the fire department. 
 

Installation and service must be performed by a qualified installer, service agency or the gas 

supplier. 
This is an unvented gas fired heater. It uses air (oxygen) from the room in which it is 
installed. Provisions for adequate combustion and ventilation air must be provided. See 
Section 2 
 
WARNING: This appliance is equipped for Natural Gas. Field conversion is not 
permitted. 

 

 

 

Содержание Old Salem Series

Страница 1: ...e or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbors phone Follow the ...

Страница 2: ...INIMUM CLEARANCE TO COMBUSTIBLES Pg 8 4 INSTALLATION INSTRUCTIONS FOR THE 20 VENTFREE ZERO CLEARANCE FIREBOX ASSEMBLAGE Pg 9 5 OPERATION Pg 9 6 CLEANING PROCEDURE Pg 9 7 GENERAL MAINTENANCE Pg 10 8 TROUBLE SHOOTING Pg 10 9 GENERAL INSTRUCTIONS IMPORTANT SAFETY INFORMATION Pg 11 10 APPLIANCE LOCATION CLEARANCE Pg 12 11 NATURAL GAS PIPING Pg 12 12 VENTING Pg 12 13 INSTALLATION INSTRUCTIONS FOR THE C...

Страница 3: ...learance Firebox This is a sheet metal enclosure for the Classic Vent free coal set We offer the Classic basket and burner as a complete unit or we can provide the Vent Free coal burner only if you wish to use another front to conceal the coal burner valve hardware 13 5 BOX DEPTH Side View 23 5 BETWEEN STUDS OLD SALEM BURNER OLD SALEM BURNER IN CLASSIC BASKET OPTIONAL FRET FRONT IN LUE OF BASKET 2...

Страница 4: ...OLD SALEM GAS COAL VENT FREE FIREPLACE Page 4 of 16 ...

Страница 5: ...OTE OR WALL SWITCH l8 GuageWire Rated 237 deg F 125 Deg C Supplied with Remote Supplied by Installer for Wail Switch Shown configured for wall switch THERMOPILE JUMPER INSTALLED ON GAS VALVE AT FACTORY 1 GENERAL INSTRUCTIONS FOR THE VENTFREE 20 ZERO CLEARANCE FIREPLACE ASSEMBLAGE IMPORTANT SAFETY INFORMATION GAS VALVE As delivered ...

Страница 6: ...faced with customer provided masonry or tile etc d No combustible materials shall be placed or burned in the firebox of this fireplace assemblage e The firebox and zero clearance box with the exhaust option is provided as a completed assembly f Cutting any sheet metal parts of the ventless firebox enclosure is prohibited g Never burn solid fuels in a fireplace where a gas coal set is installed h T...

Страница 7: ...nels at penetrations for plumbing electrical gas lines and at other openings b The Old Salem coal set has been equipped with an oxygen depletion system to prevent reduction of the oxygen level in the installation room from reaching a level below 18 percent The above requirements are provided to prevent the unlikely occurrence of this level 3 MINIMUM CLEARANCE TO COMBUSTIBLES When the Old Salem ven...

Страница 8: ...d the box Install the gas supply plumbing for the coal set in accordance with the installation operation and service manual provided If a cast iron surround is to be used install the sheetrock or fireplace surround material to the stud or masonry wall leaving a clearance of 1 inch around the firebox opening Cut a hole in the fireproof sheetrock or surround material above the firebox to match the e...

Страница 9: ...uble shooting is not applicable INSTALLATION INSTRUCTIONS FOR THE COAL SET The coal set is a ventless appliance consisting of an integrated burner control and a simulated coal fire There are no loose parts nor any field assembly required It may be configured to fit an existing grate and cover plate Cast iron surrounds are available as a decorative option 9 GENERAL INSTRUCTIONS IMPORTANT SAFETY INF...

Страница 10: ...e h Note Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that the control compartment burners and circulating air passageways of the appliance be kept clean i An unvent...

Страница 11: ... this heater or its controls can be dangerous h This appliance is intended for supplemental heating 11 NATURAL GAS PIPING a The installation must conform with local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 l NFPA 54 b Before any system of gas piping is finally put into service it should be carefully tested to ensure it is gas tight As an aid in deter...

Страница 12: ...pe to the gas input to the appliance All pipe work going through masonry should he sleeved in conduit Where pipe work is liable to come into contact with fresh cement cover with Denzo or similar electrical tape to protect the pipe from corrosion c The 3 8 flexible pipe should be no longer than 6 feet The supply pressure at the appliance should be no less than 5 inches W C for natural gas After cor...

Страница 13: ...gas control knob slightly and turn counter clockwise to OFF NOTE Knob cannot be turned from Pilot to OFF unless the knob is pushed in slightly Do not force NOTE There will be some delay after the pilot light valve is compressed before the piezo igniter will light the pilot due to the air remaining in the control valves etc If after about 3 to 5 minutes the piezo igniter still fails to light the pi...

Страница 14: ...d immediately call your service technician or gas supplier 10 Replace control access panel below grate 11 Wall switch or remote may now be used to turn main flame ON and OFF TO TURN OFF GAS TO APPLIANCE I Remove control access panel below grate 2 Push in gas control knob slightly and turn clockwise to OFF position Do not force 3 Replace control access panel below grate If a remote control system i...

Страница 15: ... from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department 18 GUARANTEE The burner and fuel effect components only are guaranteed against breakage in normal use at their replacement cost for a period of twelve months from the date of purchase All other components are guaranteed against defect in materials and workmanship for one y...

Страница 16: ...oncerned REPLACEMENT PARTS LIST Type of Control Manufacturer of Control Part Number Natural Gas ODS Valve SIT Controls 820 637 NG ODS Pilot Assembly SIT Controls 8204C Piezo Igniter SIT Controls 073 953 Four Seasons Supply Co Winston Salem North Carolina PH 336 682 3241 www coalbaskets com MADE IN THE USA ...

Отзывы: