11
1
2
1
5
LAVA rocks (7.7lbs)
Open the door (I)
For you safety,
please make sure the regulator
& hose going through under the protecting bar
.
(Fig.11)
cylinder holder
4. Turn the cylinder locking bolt clockwise to secure the
gas
cylinder. (Fig. 1
2
)
13
14
6
INSTALLATION INSTRUCTIONS
Your gas fire pit has been checked at all connections at the
factory for leakage.
LEAK TESTING
In transportation and handling some connections may have
loosened. Follow these steps to check the hose/
regulator/cylinder connections:
1) Make leakage solution by mixing 1part liquid dish soap and 3
parts water.
2) Spoon or brush several drops (or use squirt bottle) of the
solution onto hose/regulator/cylinder connection.
3) Turn on gas cylinder. Inspect the connections and look for
bubbles.
4) If no bubbles appear, the connection is safe.
5) If bubble appear, there is a leak. Turn off the cylinder valve,
loosen and re-tighten this connection. Check for leakage again.
If there is still a leak, please call customer service:1-866-814-0585.
Note:
1) The cylinder supply system must be arranged for vapor
withdrawal;
2) The cylinder used must include a collar to protect the cylinder
valve.
The hose assembly must be replaced prior to the appliance being
put into operation if there is evidence of excessive abrasion or
wear, or if the hose is damaged.
At least once a year, a complete inspection of the entire gas path
components should be performed.
If there is need to replace parts, proceed to leak test after
reassembly (These procedures should be performed by a profes-
sional technician).
1
3
1
4
P2
P1
Tighten
regulator & cylinder
connection
I
Two or more people are recommended for easier installation.
on a flat,
12
Please make sure the
regulator & hose going
through under the
protecting bar