AT Command:
AT+EXCALx=OW,<week>,<strTime>,<holdTime>
<week>: 0123456 replace to Sunday, Monday, Tuesday, Wednesday, Thursday, Friday
and Sunday ordinal.
<strTime>: Format "12:30:00"
<holdTime>: Hold time value(Unit:Second)
For example:
IP Modem power on at 09:00:00 on every Wednesday and Friday, and power off 1 hour
later.
AT+EXCAL1=OW,35,"09:00:00",3600
The “35” replace to Wednesday and Friday.
6.Power on per month
AT Command:
AT+EXCALx=OM,<date>,<strTime>,<holdTime>
<date>: 0-31
<strTime>: Format "12:30:00"
<holdTime>: Hold time value(Unit:Second)
For example:
IP Modem power on at 09:00:00 on the 28th every month,and power off 1 hour later.
AT+EXCAL3=OM,28,"09:00:00",3600