Device ID
ID number for the device. 8 characters
Phone No.
Phone number
Character Escapes
This item is only valid when the Work Mode is PROT. If this item is set
to No, IP MODEM will transfer meaning to 0xfd and 0xfe. To know
detail transfer meaning method, please refer “IP MODEM Transfer
Meaning Explanation In the PROT work mode”. If this item is set to Yes,
all the
transmission is transparent.
DCTCP
This protocol is used in electric power field, with TCP protocol.
PhoneNo.
Phone number
DCUDP
This protocol is used in electric power field, with UDP protocol
PhoneNo.
Phone number
TRNS
The device work as MODEM for sending/receiving SMS, CSD and GPRS dialing.
SMSCLI
IP MODEM work as a SMS DTU. All data will send to binding phone number via
SMS. The SMS from the binding phone number will send to Serial port.