* 362 lbs (164 kg) for a chassis loaded with blanks, with no power supplies, management modules, switch fab-
ric modules, nor interface modules.
Operating Environment
Table 8.6 provides the operating environment specifications for the NetIron MLX Series chassis.
Storage Environment
Table 8.7 provides the storage environment specifications for the NetIron MLX Series chassis.
Safety Agency Approvals
•
CAN/CSA-C22.2 No. 60950-1-03/UL60950-1 – First Edition, Safety of Information Technology Equipment
•
EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and User’s Guide
•
EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications Systems
•
EN 60950-1:2001\IEC 60950-1 Safety of Information Technology Equipment
Electromagnetic Approvals
•
FCC Part 15, Subpart B (Class A)
•
EN 55022 (CE mark) (Class A)
•
EN55024 (CE mark) (Immunity) for Information Technology Equipment
•
ICES-003 (Canada) (Class A)
•
AS/NZ 55022 (Australia) (Class A)
•
VCCI (Japan) (Class A)
•
EN 61000-3-2
•
EN 61000-3-3
NetIron MLX-16
24.47" (62.2 cm)
17.2" (43.7 cm)
25" (63.5 cm)
236 lbs (107 kg)
NetIron MLX-32
57.64" (146.4
cm)
17.45" (44.3 cm)
28.22" (71.7 cm)
561 lbs (255
kg)*
Table 8.6: NetIron MLX Series Operating Environment
Operating Temperature
Relative Humidity
Operating Altitude
32
°
– 104
°
F (0
°
– 40
°
C)
5 to 90%, at 104
°
F (40
°
C), non-condensing
0 – 6600 ft (0 – 2012 meters)
Table 8.7: NetIron MLX Series Storage Environment
Storage Temperature
Storage Humidity
Storage Altitude
-13
°
– 158
°
F (-25
°
– 70
°
C)
95% maximum relative
humidity, non-condensing
0 – 15,000 ft (0 – 4500 meters)
Table 8.5: NetIron MLX Series Physical Dimensions
NetIron MLX Series
Chassis
Height
Width
Depth
Weight (fully-
loaded)