Fostoria SUN-MITE RPH-240-A Скачать руководство пользователя страница 3

Issue Date: 06-18-99 

Rev. Date: 01-13-14 

Rev. Level 13 

ECN 1-7155 

OIPM P/N  8999

LAMP INSTALLATION

CAUTION:  Disconnect power before installing or replacing 

lamps.  They can, and should be, installed prior to mounting 

heater.

1.  Remove the housing end caps.

2.  Position quartz lamp in holes in lamp brackets at each end of 

reflector center lamp between brackets.

3.  Carefully  wrap  heating  element  pigtail  clockwise  around 

terminal  screw  (see  figure A). Avoid  handling  quartz  lamp 

as much as practical.  Lamp should be wiped off with a clean 

cloth.

4.  Tighten  terminal  screws  (see  figure  A).   

CAUTION:  Do 

not  draw  pigtail  so  tight  that  pressure  is  put  on  heating           

element.  Maintain a partial loop (or looseness) in the    

pigtail

.

5.  IMPORTANT! 

Cut excess pigtail off at terminal to 

prevent lead from touching metal parts. Failure to do so 

could result in fatal electric shock or fire.

6.  Replace end caps using sheet metal screws removed in Step 

1.

POSSIBLE LAMP FAILURE

The heating elements used in this product can be damaged by 

contamination (salt deposits from perspiration or coastal air) 

on the surface of the quartz sleeve.  At high temperatures, these 

salts will cause the quartz to become porous and leak allowing 

air to come in contact with the tungsten element.  When this 

occurs, the element will burn out quickly and the quartz tube 

can break.  The instructions below must be followed.

•  Always wear cotton or latex gloves when installing or 

replacing elements.

•  Always clean the quartz tube with an alcohol-moistened 

soft cloth before using the heater.

•  Whenever contamination (milky white appearance 

on quartz tube) is observed, the element must be 

immediately replaced.

 

Wrap pigtail clockwis

e

around screw.

Lamp

Lamp suppor

t

FIGURE "A"

Cut off

excess

MOUNTING INSTRUCTIONS 

1.  Assemble the supplied outlet box cover to the top of the heater 

using the two hex head screws.

2.  Route the two blue leads and the green (bonding) lead through 

a section of 6” conduit (supplied by customer) and thread it into 

the cover.

3.  Attach an outlet box cover to the other end of the conduit, 

make  electrical  connections  and  attach  cover  to  customer 

supplied junction box.

CAUTION: FOR TOTALLY EXPOSED OUTDOOR 

APPLICATIONS (NOT CEILING PROTECTED) THE 

CONNECTIONS MUST BE MADE AS ILLUSTRATED 

BELOW.

 

NEMA Type 4 or

equal junction box

NEMA Type 4 or equal

connection required

at locations shown

6" Condui

t

Housing

Heater

Cover

WIRING

CAUTION:

 For supply connections use number 12 AWG copper 

wires suitable for at least 90

o

C.

LAMPGUARD INSTALLATION

To install the optional lampguard (Model RPHWG):

1.  Remove the screws and end cap from one end of the heater.

2.  Insert the lampguard into the holes provided in each end cap.

3.  Replace  the  end  cap  and  screws  removed  in  step  1.  (See 

illustration below.)

Heater housing

Screw

End Cap

Lampguard

MAINTENANCE

Always  disconnect  the  heater  from  the  power  source 

before performing any service or maintenance.

Periodically clean the reflector with a soft damp cloth, using a 

mild detergent.  Rinse with water and wipe dry with a clean soft 

cloth.

Page 3 of 3